Herunterladen Inhalt Inhalt Diese Seite drucken

Installation Of The Inside Unit - Olimpia splendid UNICO TWIN MASTER Hinweise Für Die Verwendung Und Pflege

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

2.4.1 -

INSTALLATION OF THE INSIDE UNIT

INSTALLATION OF FASTENING PLATE
After checking what is described in paragraph "2.2", proceed with the mounting of the fixing plate (L1), con-
sidering the dimensions indicated in figure "B".
a. Position the plate against the wall.
b. mark the drilling points, making sure that they are level.
c. make the holes necessary in the wall using a suitable bit.
Make sure there are no pipes or electric ducts in the drilling area.
d. Insert the plugs (H) into the holes and fix the plate (L1) to the wall using the screws (H) supplied (figure
23).
Using a spirit level, make sure that the fixing plate (L1) is level.
e. if the wall is in wood, use relevant countersunk-head screws (not supplied).
f. Check the stability of the plate (l1), moving it laterally and vertically.
REALISATION OF PIPE PASSAGE HOLES
if the connection lines arrive from the rear right of the indoor unit, a hole "R" must be made for passage of
the piping, as successively described (see figure B).
a. make a 8÷10 mm hole in the centre of the position "R", with slope towards the outdoors of 5% (to allow
condensate to be drained correctly (figure 9).
b. make the hole "R" using a core drill with the diameter indicated in the table of figure "B".
c. insert the drain line piping and that of refrigeration into the hole along with the electric connection cable.
if the connection lines arrive from the rear left of the indoor unit, a hole "L" must be made for passage of the
piping (see figure B).
B
L
ø
H
L
mm
101,6
fixing bracket
indoor unit
R
H
mm
mm
115,6
47
R
ø
H
ø
mm
65
EN - 17
UNICO TWIN

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Unico twin wall