2.2 - CHOOSING THE POSITION OF THE UNIT

to obtain the best operating performance and prevent faults or hazardous conditions, the position of indoor
unit installation must meet the following requirements:
a. Do not expose the appliance to heat or steam sources (fig. 3).
b. make sure that the space to the right and left is at least 60 mm and space above the unit is at least 80
mm. (fig. 2).
c. The height of the unit's lower edge from the floor should be at least 100 mm if fixed to the wall in the
lowest position. If fixed to the wall in the highest position, it should be at least 80 mm from the ceiling
(fig. 2).
d. UNICO WALL cannot be installed at a height lower than 2 meters from the floor.
The wall where the indoor unit is to be fixed, must be stable, strong and suitable to support the weight.
e.
it must be possible to leave room around the unit for any maintenance operations that may be necessary.
f.
nothing should be in the way of the air that needs to circulate both on the top air-intake (curtains, plants,
furniture) and at the front where the air exits. this could cause air swirls that would inhibit the working
efficiency of the unit (fig. 3).
g. Do not spray water or other liquids of any kind directly on the unit (fig. 3).
h. The appliance must not be positioned so that the air flow is directed directly towards nearby people (fig.
3).
i.
Never force the opening of the airflow flap (fig. 3).
l.
Do not place bottles, cans, clothes, flowers or any other object on the air suction grille (fig. 3).
m. Do not install the air conditioner directly on another household appliance (tv, radio, fridge, etc.), or on
a heat source (fig. 3).
The air conditioner must be installed on a wall that communicates with the outside
After determining the best place for installation as described above, check for
the absence of other structures or systems (beams, piers, pipes, wires, etc.) at
the points where the holes are to be drilled, which would prevent drilling the
holes required to install the unit.
Check again to make sure there are no obstacles to air circulation through the
holes to be drilled due to plants and their leaves, slats or panelling, blinds, grat-
ings or grids too dense, etc.).

2.3 - INSTRUCTIONS FOR INSTALLATION UNICO MASTER

to obtain the best results and optimum performance, follow the instructions for correct installation provided
in this manual.
A failure to implement the indicated standards, which may cause a malfunction
of the appliances, relieves OLIMPIA SPLENDID from any form of warranty and
from any liability for possible damages caused to people, animals or things.
The electrical system must be compliant with legal standards, must respect
the data in the technical data sheet and be must be equipped with an efficient
ground system.