BFT SP 3500 Installations- Und Gebrauchsanleitung Seite 22

Trieb für schiebetore mit zahnstange
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 36
Terminal
L1
L2
L3
N
L1
L2
L3
20
21
26
AUX 3 - FREE CONTACT (N.O.)
27
41
42
43
50
51
52
60
61
62
63
64
65
70
71
72
73
74
75
76
77
78
Y
#
ABCD
EFGH
RST
22 -
SP 3500 - SP 3500 SF
INSTALLATION MANUAL
Definition
LINE - R
LINE - S
Three-phase Power supply 380-400V, 50-60Hz.
LINE - T
NEUTRAL
LINE - R
LINE - S
Three-phase Power supply 220-230V, 50-60Hz.
LINE - T
LIGHT 230V
Flashing light 230V output max. 40W.
Contact N.O. (24V~/3W max).
(Max. 24V 3W)
Can only be used with second channel of radio-receiver plugged into relevant connector.
Limit switch common
+ REF SWE
Pass the connection of the common limit switch through the N.C. contact (95-96) of the K0 thermal relay
SWC
Closing limit switch SWC (N.C.).
SWO
Closing limit switch SWO (N.C.).
24V-
Accessories power supply output.
24V+
Tested safety device power supply output (photocell transmitter and safety edge transmitter).
24 Vsafe+
Output active only during operating cycle.
Common
IC 1 and IC 2 inputs common
Configurable command input 1 (N.O.) - Default START E.
IC 1
START E / START I / OPEN / CLOSE / PED / TIMER / TIMER PED
Refer to the "Command input configuration" table.
Configurable command input 2 (N.O.) - Default PED.
IC 2
START E / START I / OPEN / CLOSE / PED / TIMER / TIMER PED
Refer to the "Command input configuration" table.
Common
IC 3 and IC 4 inputs common
Configurable command input 3 (N.O.) - Default OPEN.
IC 3
START E / START I / OPEN / CLOSE / PED / TIMER / TIMER PED
Refer to the "Command input configuration" table.
Configurable command input 4 (N.O.) - Default CLOSE.
IC 4
START E / START I / OPEN / CLOSE / PED / TIMER / TIMER PED
Refer to the "Command input configuration" table.
Common
STOP, SAFE 1 and SAFE 2 inputs common
The command stops movement. (N.C.)
STOP
If not used, leave jumper inserted.
Configurable safety input 1 (N.C.) - Default PHOT.
PHOT / PHOT TEST / PHOT OP / PHOT OP TEST / PHOT CL / PHOT CL TEST / BAR / BAR TEST / BAR 8K2
SAFE 1
TEST / BAR 8K2 OP / BAR CL / BAR CL TEST / BAR 8K2 CL.
Refer to the "Safety input configuration" table.
FAULT 1
Test input for safety devices connected to SAFE 1.
Configurable safety input 2 (N.C.) - Default BAR.
PHOT / PHOT TEST / PHOT OP / PHOT OP TEST / PHOT CL / PHOT CL TEST / BAR / BAR TEST / BAR 8K2
SAFE 2
TEST / BAR 8K2 OP / BAR CL / BAR CL TEST / BAR 8K2 CL
Refer to the "Safety input configuration" table.
FAULT 2
Test input for safety devices connected to SAFE 2.
Common
SAFE 3 input common
Configurable safety input 3 (N.C.) - Default PHOT OP.
PHOT / PHOT TEST / PHOT OP / PHOT OP TEST / PHOT CL / PHOT CL TEST / BAR / BAR TEST
SAFE 3
BAR CL / BAR CL TEST.
Refer to the "Safety input configuration" table.
FAULT 3
Test input for safety devices connected to SAFE 3.
ANTENNA
Antenna input.
Use an antenna tuned to 433MHz. Use RG58 coax cable to connect the Antenna and Receiver. Metal bodies close to the
antenna can interfere with radio reception. If the transmitter's range is limited, move the antenna to a more suitable position.
SHIELD
Internal wiring
See wiring Fig. P-Q
Description
Fig. F
Fig. F
2 / BAR OP / BAR OP
/ BAR OP / BAR OP
/ BAR OP / BAR OP TEST /