4. Installation

C
B

Installing the tap

Note: The tap must not be installed more than 900 mm above the base of the
Tap
undersink unit. Failure to do this may result in poor water delivery.
Note: Under no circumstances should the tap be twisted after the installation is
complete.
Spacer
1. Make sure that the tap location will allow water from the tap to fall into a sink or
other basin fitted with a drain to drain away.
2. Cut a 35 mm diameter hole in the worktop / sink at the place where the tap is to be
installed.
3. Push the black spacer on to the tap from underneath and ensure it remains in
position. A light smearing of silicone sealant on the underside of the spacer will
ensure a watertight fit.
S/S washer
4. Pass the hoses down through the 35 mm hole in the worktop / sink and locate the tap
head on its mounting location.
5. From the underside, push the stainless steel washer over the hoses and then push the
Spider clamp
spider clamp on to the threaded rod of the tap fitting. Secure the spider clamp with
the fastening nut. Check the tap head is in the correct position before tightening up
the nut.
Fixing nut

Installing the undersink unit

Note: An air gap of at least 50 mm at the left and right of the unit must
be provided for adequate ventilation. If the unit is to be operated inside a
cupboard, the supplied silicone buffers should be affixed to the inside edge of
the cupboard doors and the ventilation grills should be installed.
Please note the installation drawing below:
A
285.00
B
314.00
326.00
A
C
19
The cut outs A and B can be covered with
the provided ventilation grilles.
The provided ventilation shaft has to be
mounted on the device and placed in the
cut out C. It will lead the warm air under
the cupboard floor, from where it can
escape through cut out A.
There must be a distance from at least
10cm between the cut outs A and B, to
avoid a thermal short circuit.