Herunterladen Inhalt Inhalt Diese Seite drucken

Approvals; Use Limitations; Inspection Procedure; Instructions For Fitting Prior To Use - 3M 7907S Gebrauchsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 14
O-QX65-MAC10-DV-2563-0244-6-bklet1.qxd:7714-3M Booklet 7907S-rv

3. Approvals

This product meets the requirements of European Standard EN
136:1998 CL2. This product meets the requirements of the European
Community Directive 89/686/EEC (Personal Protective Equipment
Directive) and is thus CE marked. Certification under Article 10, EC
Type-Examination, has been issued for these products by Dekra Exam
GmBH, Dinnendahlstr, 9.44809, Bochum (Notified Body number
0158).Certification under Article 11A, EC quality control, has been
issued by Institut fuer Arbeitsschutz der DGUV (IFA)(Notified Body
number 0121).

4. Use limitations

This respirator does not supply oxygen.
DO NOT USE IN OXYGEN DEFICIENT ATMOSPHERES
Do not use for respiratory protection against atmospheric
contaminants which have poor warning properties, or are unknown or
immediately dangerous to life and health or against chemicals which
generate high heats of reaction with chemical filters.
Remark: the S-200 Supplied-Air Respirator System can be used with
contaminants with poor warning properties. (Subject to other use
limitations).
Leave work area immediately, check integrity of respirator and
replace parts if:
a) parts become damaged
b) breathing becomes difficult or increased breathing resistance
occurs
c) dizziness or other distress occurs, or
d) you taste or smell the contaminants or an irritation occurs.
Use strictly in accordance with the facepiece and filter instructions,
labels and limitations pertaining to this respirator assembly. If you
have any doubts about the application to your job situation, it is
recommended you consult an Occupational Hygienist or call 3M
OH&ES Technical Affairs at your nearest 3M office. See back of this
booklet for addresses and telephone numbers.
Use of this or any respirator should be in accordance with applicable
safety and health standards, respiratory selection tables or pursuant to
the recommendations of an Occupational Hygienist.
The assembled respirator may not provide a satisfactory face seal with
certain physical characteristics (such as beards or large sideburns)
resulting in leakage between the facepiece and the face, which voids
or limits the protection.
If such conditions exist, the user assumes all risks of bodily injury
3M definition minimum 19.5% by volume oxygen.
1
4/11/10
15:24
which may possibly result.
Never modify or alter this device.
Only for use by trained and qualified personnel.
Store this device in a sealed container away from contaminated areas
when not is use.

5. Inspection procedure

This respirator must be inspected before each use to ensure it is in
good operating condition. Any damaged or defective parts must be
replaced before use. The following inspection procedure is suggested:
Check the facepiece for cracks, tears and dirt. Be certain the
facepiece, especially the face seal area, is not distorted.
The material must be pliable - not stiff.
1
Examine the inhalation valves for signs of distortion, cracking or
tearing. Lift valves and inspect valve seal for dirt or cracking.
Ensure that the head straps are intact and have good elasticity.
Examine all plastic parts for signs of cracking or fatigue; make sure
the gaskets are properly seated.
Remove the exhalation valve cover and examine the exhalation valve
and valve seat for signs of dirt, distortion, cracking or tearing. Replace
the exhalation valve cover.
The lens should be clean and free from any cracking or fatigue.
Test by tapping with hard object (such as a closed fist), to check for
embrittlement.

6. Instructions for fitting prior to use

6.1. Assembly instructions
• Before attaching the filters ensure that gaskets are in place on
facepiece bayonet connector.
• For correct filter use see the relevant instruction leaflet and
the scheme on page 1 of this leaflet.
• When attaching the filters to the facepiece ensure that the
filters are of identical type and class.
6.2. Donning and Fitting (Fig. 1-2)
Fully loosen all 6 headstraps, then place the harness
at the back of the head and pull the facepiece down over
the face.
Pull the ends of the 6 straps to adjust the tightness, starting
with the neck straps first, followed by the temple straps; do not
tighten the headstraps too tightly as this may deform the nose
cup and narrow the inhalation air passage.
3
Page 3

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis