12. Settings

12.1 Parameter

Dis-
Description
Code Unit Min. Max. Options
play
P1
Set room temperature -
P2 Intensive ventilation
-
runtime
P3 Passive cooling oper-
-
ating mode
P4
Reset filter
-
P6
Flow rate, stage 0
A1
P7 Flow rate, stage 1
A1
P8 Flow rate, stage 2
A1
P9 Flow rate, stage 3
A1
P14 Supply air flow rate
A1
offset
P15 Humidity protection
A1
interval
P16 Start-up time for hu-
A1
midity measurement
P17 Extract air humidity
A1
limit
P18 Frost protection tem-
A1
perature
P19 Filter change interval A2
P22 Enable preheater
A1
P24 Passive cooling re-
A1
lease temperature
P25 Passive cooling block-
A1
ing temperature
P26 Passive cooling hys-
A1
teresis
P27 Temperature differ-
A1
ential for enabling
passive cooling
P70 Delete fault list
A1
P80 Day
-
P81 Time
-
P82 Illumination level
-
P83 Mode of backlighting -
P84 Illumination duration -
P85 Lower standard dis-
-
play
The "service/fault" symbol appears when scrolling through the
parameter list for all parameters that are reserved for qualified
contractors and are only accessible by entering a code.
40
|  LWZ 130 
326794-40317-9268_LWZ_130_de_en.indb 40
Stand-
ard
°C
5
28
20
min 1
240
0 | 1 | 2 | 3
2
1 | 0
0
m³/h 50
100
m³/h 70
120
m³/h 90
140
m³/h 110
180
m³/h -100 100
0
h
1
24
1
min 5
15
%
5
95
65
°C
-5
15
2
d
1
365
90
0 | 1
1
°C
5
15
10
°C
5
15
8
K
0
5
2
°C
0
5
2
0 | 1
0
1 - 7
00:00 23:59
2
10
10
Auto | On |
Auto
Off
s
10
500
60
Off | Time |
Off
Set room
tempera-
ture | Extract
air tempera-
ture | Extract
air humidity
„P14 : Supply air flow rate offset
Use this parameter to adjust the supply air flow rate during com-
missioning. The offset relates to standard ventilation. The offset
is converted internally as a percentage for the other fan stages.
Example
- Nominal flow rate (stage 2) : 125 m³/h
- Offset : 25 m³/h
Stage Set flow 
Off-
Set flow 
rate
set
rate + off-
set
0
50
1
90
2
125
25 125+25 = 150 150/125 = 1.2 125x1.2 = 150
3
180
„P15 : Humidity protection interval
If you set fan stage 0, the appliance switches to a 24 hour dormant
phase. The humidity protection control unit only starts after this.
The appliance measures the humidity of the extract air for the
time set in P16. The appliance compares the last measured value
with the limit value set in P17. If the limit value is exceeded, the
appliance starts to ventilate. The appliance stops the ventilation
once the limit value is fallen below. At this point, the humidity
protection interval restarts, at the end of which the moisture is
measured.
„P16 : Start-up time for humidity measurement
The appliance measures the humidity of the extract air for the time
set in P16. The appliance compares the last measured value with
the limit value set in P17.
„P22 : Enable preheater
Options
Effect
0
The internal preheater is completely deactivated.
1
The internal preheater is activated. In order to keep the heat ex-
changer free from ice, the preheater ensures a minimum supply
air temperature with reference to the frost protection tempera-
ture adjustable in parameter P18.
While this parameter is being displayed or adjusted, the "frost
protection" symbol is shown on the display.
„P24 : Passive cooling release temperature
To enable checking of the other parameters for passive cooling,
the outdoor air temperature must be no less than the value set
in this parameter.
„P25 : Passive cooling blocking temperature
If the outdoor air temperature falls below this blocking tempera-
ture, passive cooling is deactivated.
Offset 
Internal set flow 
factor
rate = set flow 
rate x offset factor
50x1.2 = 60
90x1.2 = 108
180x1.2 = 216