GB
Application
Prod. no. 36 111:
Single-hole mixer suitable for:
• Direct connection to cold water supply
• Connection to outlet of mixed water supply
Prod. no. 36 109 and 36 110:
Can be used in conjunction with:
• Pressurised storage heaters
• Thermally controlled instantaneous heaters
• Hydraulically controlled instantaneous heaters
Operation with unpressurised storage heaters (displacement
water heaters) is not possible.

Technical Data

• Flow pressure
• Operating pressure
• Test pressure
If static pressure is greater than 5 bar,
fit a pressure-reducing valve.
• Flow rate at 3 bar flow pressure
• Infinitely variable running time from 5 - 40 s
(factory setting: 15 s)
Prod. no. 36 109 and 36 110:
• Temperature
Hot water inlet
• Water connection
Note
Avoid major pressure differences between hot and
cold water supply.
Installation
Flush pipes thoroughly.
Failure
Fault
Fitting does not close
- flow is too low
- cartridge defective
- O-ring damaged
Fitting does not open
- service valve closed
- cartridge defective
Flowtime too short or too long
- wrong setting
- cartridge defective
Flow volume too small
- dirt strainers blocked
- service valve not fully open
- mousseur clogged with limescale
Hot water forced into cold water line
- non-return valve dirty or defective
Installation
Refer to the dimensional drawings on fold-out page I.
Fasten fitting to wash basin
Connection
The cold water supply must be connected on the right and the
hot water supply on the left.
Screw adapter together with seal onto the service valve.
Replacing the cartridge, see Figs. [1] and [2].
Setting the water flow time, see Figs. [5] and [6].
• Align toothed disc (A), see Fig. [5].
• Attach pushbutton cap (B), ensuring that toothed disc (A) is
still free to turn.
Adjustment of water flow time is infinitely variable
from 5 - 40 s (2.5 s for one complete rotation).
Setting the desired maximum temperature, see Figs. [5]
and [7] to [9].
1.2 - 5 bar
• Align toothed disc (A), see Fig. [5].
max. 10 bar
• Attach pushbutton cap (B) and set the desired maximum
16 bar
temperature, see Fig. [7].
• Remove pushbutton cap (B).
• Mark toothed disc (A) level with left stop (C), see Fig. [8].
approx. 6 l/min.
• Realign toothed disc (A), see Fig. [9].
Assemble, in reverse order.
In order to ensure permanent, trouble-free operation,
max. 60 °C
installation of the enclosed adapter with dirt strainer and
non-return valve is mandatory.
cold - right
hot - left
Open hot and cold water supply and check connections
for leakage.
Replacement parts, see fold-out page I (* = special
accessories).
Care
For directions on the care of this fitting, please refer to the
accompanying Care Instructions.
Remedy
• check
• replace cartridge and if necessary O-ring
• replace
• open
• replace cartridge and if necessary O-ring
• set flow time
• replace cartridge and if necessary O-ring
• clean
• open
• clean
• clean or replace
Figure
1 - 4
3
1 - 4
5 - 6
1 - 4
11 - 12
11 - 12