INsTALLATIoN

Appliance description

3. Appliance description
3.1

Equipment overview

Earth conductor intermediate connection
Mains feed-through terminal, pump/boiler circuit
Mains feed-through terminal, dew point sensor
Advanced pump/boiler control: Run-on time configurable
simple pump control
signal input for temperature limiter or dew point sensor
setback channel for connection of external timers
Connection for heating/cooling changeover signal
Timer module: Enclosure cover with integral system clock
Mode of operation: Normally closed (NC) / normally open (No)
LED indicator
x
Installed
-
N/A
**
Also No without pump control

3.2 Appliance overview

1
2
1
Pump control connection
2
Earth conductor intermediate connection
3
Power supply
Mains feed-through terminal
4
Fuse
5
Temperature limiter or dew point sensor connection switching contact for connecting a temperature limiter or dew point sensor:
6
setback channel for connection of external timers
7
Heating/cooling changeover
8
Controller connection
9
Cable entry and strain relief
10 Actuator connection
14 |
3
4
5
6
7
10
Floating contact for controlling a pump circuit
Predefined start and stop delay (2 minutes)
Pump circuit: Cyclical control of the pump (every 14 days for 1 minute)
Terminal for intermediate connection of the earth conductor of electrical consumers (e.g. pump)
Appliance power supply
Mains feed-through terminal for connecting electrical consumers (e.g. pump)
Interruption of the power circuit if certain threshold values are exceeded
Temperature limiter prevents excessive underfloor heating flow temperatures via a floating
contact.
Dew point sensor monitors the system in cooling mode and switches it off if condensation is
detected.
Transmission of up to 2 timer signals for time-controlled setback of the room temperature to
connected controllers via a floating contact
Changeover of the entire individual room control system between heating and cooling
supply of an external signal via floating contact
Forwarding of the changeover signal to connected controllers
Power supply for up to 10 connected controllers
Cable entry and strain relief according to EN 60730-1
Power supply for connected actuators
Valve protection function on all outputs (optional):
The valves are prevented from seizing up through cyclical control of the actuators
E10-RKL
E10-RKL2
Z10-RKL
238974
238975
239034
x
x
x
x
-
-
-
-
x
x
x
x
x
x
x
x
-
-
NC**
NC**
NC**
-
-
8
9
Z10-RKL2
239035
x
x
x
x
-
-
-
-
x
x
x
x
x
x
x
x
-
-
NC**
-
-
E10 RKL, Z10 RKL