Herunterladen Inhalt Inhalt Diese Seite drucken

Interlogix VE1120 series Installationsanleitung Seite 3

Vorschau ausblenden Andere Handbücher für VE1120 series:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 9
7
(1)
VE1120
J4
J3
CP
Normal
A
larm
(2)
VE1120
J4
J3
CP
Ω
Normal
4.7 k
A
larm
9.4
Tamper
Ω
Short
0
EN: Installation Sheet
Description
The VE1120 series includes:
VE1120 PIR motion sensor
VE1120AM PIR motion sensor with anti-masking
They have a patented mirror, pyro, and signal processing
technology.
Note:
Only VE1120 has been evaluated by UL/cUL.
Installation guidelines
The technology used in these detectors resists false alarm
hazards. However, avoid potential causes of instability (see
Figure 1) such as:
Direct sunlight on the detector
Strong draughts onto the detector
Heat sources within the detector field of view
Animals within the detector field of view
P/N 146279999-2 (ML) • REV H • ISS 11MAR19
< 33 Ω
J4
J3
J4
J3
J4
J3
Ω
Normal
4.7 k
A
larm
9.4
Tamper
Ω
Short
0
VE1120AM
J4
J3
CP
< 33 Ω
Normal
A
larm
VE1120AM
J4
J3
CP
Ω
Normal
4.7 k
A
larm
9.4
Tamper
Ω
Short
0
AM/TF
Obscuring the detector field of view with large objects,
such as furniture
Objects within 50 cm (20 in.) of the anti-masking (AM)
detector
Installing two detectors facing each other and less than
50 cm (20 in.) apart (only AM detectors)
Installing the detector
Figure 7
(1)
Standard connection (factory default)
(2)
Dual loop connection
CP
Control panel
WT
Walk test
AM
Antimasking
D/N
Day/night
Rtest
Remote test
To install the detector:
1.
Lift off the custom insert and remove the screw
(see Figure 2, step 1).
2.
Using a screwdriver, carefully prise open the detector (see
Figure 2, steps 2 and 3).
J4
J3
J4
J3
J4
J3
CP
Ω
Normal
4.7 k
A
larm
9.4
Tamper
Ω
Short
0
AM/TF
3 / 36

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Ve1120Ve1120 am

Inhaltsverzeichnis