Herunterladen Diese Seite drucken

Transport; Installation; General; Acoustic Emissions - Dimplex SI 35TUR Montage- & Bedienungsanleitung/Gebrauchsanweisung

Vorschau ausblenden Andere Handbücher für SI 35TUR:

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

SI 35TUR
5

Transport

A lift truck is suited for transporting the unit on a level surface.
The device can be lifted from the rear or front on even ground
using a lift truck or fork-lift truck for transportation.
ATTENTION!
The heat pump must not be tilted more than 45° (in any
direction).
After transportation, the transport fastening in the device is to
be removed from both sides of the base.
A
A
ATTENTION!
Before commissioning, the transport fastening must be
removed.
All panelling can be removed to allow accessing the inside of
the device.
To remove the panelling, open the individual covers by un-
screwing the respective screw fasteners and then gently tilting
the covers away from the device. Then lift them up out of the
mountings.
www.gdts.one
6

6.1 General

The brine-to-water heat pump must be installed in a frost-free,
dry room on an even, smooth and horizontal surface. The entire
base of the frame should lie directly on the floor to ensure an
adequate soundproof seal. If this is not the case, additional
sound insulation measures may be necessary.
The heat pump must be installed so that maintenance work can
be carried out without hindrance. This is ensured when observ-
ing the distances to solid walls as shown in the figure.
Neither frost nor temperatures higher than 35 °C must occur in
B
the installation location at any time of the year.

6.2 Acoustic emissions

B
The heat pump operates quietly due to efficient sound insula-
tion. Internal insulation measures should be carried out to pre-
vent vibrations from being transmitted to the foundation or to
the heating system.
7
7.1 General
The following connections need to be established on the heat
pump:
452237.66.54 · FD 9912

Installation

0,7 m
Connection side
Operating side
1,0 m

Assembly

Flow and return of the brine (heat source system)
Flow and return of the heating system
Power supply
Temperature sensor
English
0,7 m
EN-5

Werbung