WARNING!
BUILT IN NATURAL GAS HOOK-UP: The piping up to the gas grill is the responsibility of the installer and
piping should be located as shown in the built-in instructions. A flexible metal connector is included to
simplify the installation of the unit. Connect this connector to the flare fitting on the end of the manifold.
Connect the other end of the connector to the gas piping. Ensure that the connector does not pass
through a wall, floor, ceiling or partition, and is protected from damage. Do not use a hose to connect the
unit. It must be connected with rigid pipe, copper tube or an approved flexible metal connector which
complies with national and regional codes. The installation must comply with national and regional codes.
The gas supply pipe must be sufficiently sized to supply the kW input specified on the rating plate, based
on the length of the piping run. If installing a side burner, a separate line must be branched off to the side
burner unit and enter the side burner opening at the specified location.
!
WARNING!
grease. To prevent grease fires, the pan must be cleaned after each use.
WARNING!
DANGER!
!
instructions exactly could result in a fire causing serious injury or death. The entire installation must be
leak tested before operating the grill.
!
N415-0541CE-GB-DE JuNE 04.19
N415-0541CE-GB-DE.indd 7
The cylinder valve(s) must be readily accessible for hand operation. A door on the enclosure to gain
access to the cylinder valves is acceptable, provided it is non-locking and can be opened without the
use of tools.
The enclosure for the LP-gas cylinder must isolate the cylinder from the burner compartment to
provide shielding from radiation, a flame barrier, and protection from foreign material, such as hot
drippings. The enclosure cannot be located directly below the grill.
There must be a minimum clearance of 51 mm between the floor of the LP-gas cylinder enclosure
and the ground.
The enclosure must be designed so that the LP-gas cylinder can be connected, disconnected and
the connections inspected and tested outside the cylinder enclosure. Any connections that can
be disturbed when installing the cylinder in the enclosure must be accessible for testing inside the
enclosure.
Built in units are supplied with a drip pan which holds only a minimal amount of
Access must be provided to the inside of the enclosure to make gas connections.
Read all instructions carefully before operating the grill. Failure to follow these
Electrical Precautions
WARNING!
Failure to follow these instructions could result in property damage, personal injury or
death.
230 - 240V / AC - 50HZ – 0.4A.
To protect against electric shock, do not immerse cord or plugs in water or other liquid.
unplug from the outlet when not in use and before cleaning. Allow to cool before putting on or
taking off parts.
Do not operate any outdoor cooking gas appliance with a damaged cord, plug, or after the appliance
malfunctions or has been damaged in any manner. Contact the manufacturer for repair.
If the supply cord is damaged, it must be replaced by the manufacturer or its service agent or a
similarly qualified person in order to avoid a hazard.
Do not let the cord hang over the edge of a table or touch hot surfaces.
Do not use an outdoor cooking gas appliance for purposes other than intended.
When connecting, first connect plug to the outdoor cooking gas appliance then plug appliance into
the outlet.
use only a Ground Fault Interrupter (GFI) protected circuit with this outdoor cooking gas appliance.
Never remove the grounding plug or use with an adapter of 2 prongs.
use only extension cords with a 3 prong grounding plug, rated for the power of the equipment, and
approved for outdoor use with a W-A marking.
7
EN
www.napoleon.com
6/4/2019 10:28:50 AM