Caution!
Never operate the machine if the safety and monitor-
ing devices have been removed or damage, or if they
do not work.

2.8. Pumped fluids

Each pumped fluid differs in regard to composition, cor-
rosiveness, abrasiveness, TS content and many other
aspects. Generally, our products can be used for many
applications.
For more precise details, see chapter 3, the machine data
sheet and the order confirmation.
It should be remembered that if the density, viscosity or
the general composition change, this can also alter many
parameters of the product.
Different materials and impeller shapes are required for
different pumped fluids. The more exact your specifica-
tions on your order, the more exactly we can modify our
product to meet your requirements.
If the area of application and/or the pumped fluid change,
we will be happy to offer supportive advice.
When switching the product into another pumped fluid,
observe the following points:
Products which have been operated in sewage or
waste water must be thoroughly cleaned with pure
water or drinking water before use.
Products which have pumped fluids which are haz-
ardous to health must always be decontaminated
before changing to a new fluid. Also clarify whether
the product may be used in a different pumped fluid.
With products which have been operated with a lu-
bricant or cooling fluid (such as oil), this can escape
into the pumped fluid if the mechanical shaft seal is
defective.
Danger - explosive fluids!
It is absolutely prohibited to pump explosive liquids
(e.g. gasoline, kerosene, etc.). The products are not
designed for these liquids!

2.9. Sound Pressure

Depending on the size and power (kW), the pump has a
sound pressure of about 40dB (A) to 70dB (A) during op-
eration. However, the actual sound pressure depends on
several factors.
These are, for example, the type of installation and set-up,
mounting of accessories, piping, operating point, immer-
sion depth, and much more.

3. General Description

3.1. Utilization

The wastewater lifting unit Sanipower promotes contam-
inated water and wastewater drainage from sinks, show-
ers, washing machines and toilets, from areas below the
backflow level and from areas for which the slope to the
nearest sewer connection is too low. The pH value of the
promoting medium may fall between 5 and 11.

3.2. Type of application

The wastewater lifting unit is designed for 30% S3 inter-
mittent operation with a switching frequency of15 cycles
per hour.

3.3. Structure

The wastewater lifting units consist of a non-rotting,
water-, gas- and odor-tight plastic container with a sin-
gle-stage centrifugal pump. The container has a horizontal
inlet DN100, a vertical inlet DN50, a horizontal pressure
outlet and a ventilation valve DN25.
The system has a control unit for controlling and monitor-
ing all key functions:
Pneumatic level control with pressure operation
Electronic control box with variable follow-up phase
Motor protection
Temperature monitoring of the winding with auto-
matic re-start
Technical Data
Power consumption
Motor power
Voltage
Speed
Nominal current
Pump protection system
Control unit
protection system
System weight
Useable volume container
Permitted medium temperature
Free throughput
Pressure outlet
Sanipower
1.5 kW
1.1 kW
230V / 1Ph
2900 rpm
7 A
IP 68
IP 54
32 kg
11 l
35°C
Cutter
R 2" AG
EngliSH | 21