3.4.3.
Choosing input mode
For each tuner, an input mode can be selected.
•
Default
The programs can be assigned to the respective modulators in remux mode or distributed to different
modulators in or in cross-multiplex mode
•
Select all
Each program is activated for the modulator. If the option is activated, then no settings can be made in
the columns LCN, Decrypt etc.
•
Transmodulator
The programs and information (PIDs, NIT etc.) are transmitted 1 : 1 from the tuner to the modulator.
Nothing is changed and nothing can be changed.
3.4.4.
LCN (Logical Channel Numbering)
During the scan of TV stations, the stations are usually saved in the sequence of the channel lists in tuner 1-4.
The LCN function enables channel allocation for the station scan of the TV devices. The TV device must support
the LCN function.
•
LCN can be used in REMUX as well as in Cross-Multiplex-Mode.
•
Different LCN standards can be selected with the drop down menue Region. This standard may vary from
area to area.
•
An LCN can only be entered for programs assigned to a modulator.
Click on the LCN column for the corresponding program.
Enter the LCN with the keyboard or increase / decrease the LCN with the arrow buttons right of the number.
Enter a separate LCN for each desired program.
To clear the LCN, enter 0 in the LCN column.
Click SAVE CHANGES.
The numbers of the channels are saved.