ADJUSTMENTS
Accessory Installation
Always turn off the air supply and disconnect the air
supply hose before installing, removing or adjusting any
accessory on this tool or before performing any
maintenance on this tool.
To install or remove a Chisel or other accessory, hold the
tool by the Casing (18) and push hard on the Bit Retainer
(22).
LUBRICATION
Ingersoll- -Rand No. 10
Always use an air line lubricator with these tools.
We recommend the following Filter- -Lubricator- -Regulator
Unit:
For International - - No. C01- -C2- -T29
Before attaching the air hose, place about 3 cc of
Ingersoll- -Rand No. 10 Oil into the air inlet. This should be
done each day, even when an air line lubricator is used.
During the working day, check the tool to ensure that the
retainer components are lubricated.
After each two or three hours of operation, if an air line
lubricator is not used, disconnect the air hose and pour
about 3 cc of Ingersoll- -Rand No. 10 Oil into the air inlet of
the tool.
If the action of the Scaler becomes sluggish, pour about
3 cc of a suitable cleaning solution into the air inlet and run
the tool for not more than thirty seconds. Immediately after
flushing the tool, pour about 3 cc of Ingersoll- -Rand No. 10
Oil into the air inlet and run the tool for about thirty
seconds to lubricate internal parts.
Model
125- -EU
Tested in accordance with PNEUROP PN8NTC1.2 under load
H
Tested in accordance with ISO8662- -2
PLACING TOOL IN SERVICE

SPECIFICATIONS

Blows
Piston Stroke
per min.
in (mm)
4,600
1- -1/8 (28.6)
Before storing a Scaler or if the Scaler is to be idle for a
period exceeding twenty- -four hours, pour about 3 cc of
Ingersoll- -Rand No. 10 Oil into the air inlet and operate the
tool for 5 seconds to coat the internal parts with oil.
Before storing Air Hammer or if the tool is to be idle for
a period exceeding 24 hours, pour about 3 cc of
Ingersoll- -Rand No. 10 Oil into the air inlet and operate the
tool for 5 seconds. This will coat the internal parts with oil
and prevent rusting while the tool is idle.
Never use a heavy oil or an oil that forms gum. Either
will clog the small parts, restrict valve motion and cause
loss of efficiency. If the operation of the Hammer becomes
sluggish, pour 3 cc of a clean, suitable cleaning solution
into the air inlet and operate the tool for 30 seconds.
Lubricate in the regular manner immediately after flushing.
MAIN LINES 3 TIMES
AIR TOOL INLET SIZE
TO
AIR
SYSTEM
TO
AIR
TOOL
LUBRICATOR
FILTER
REGULATOR
BRANCH LINE 2 TIMES
AIR TOOL INLET SIZE
DRAIN REGULARLY
HSound Level
dB (A)
Pressure
99.6
3
COMPRESSOR
(Dwg. TPD905- -1)
♦Vibrations
Level
2
Power
m/s
112.6
32.9