Tool Inspection

WARNING
Daily before use, inspect your electrical tool and
cor rect any problems to reduce the risk of serious
injury from electric shock, crushing injures, inter-
changeable head failure and other causes, and pre-
vent tool damage.
1. Make sure that the electrical tool battery is removed.
Inspect the battery for damage. If any damage or
modifications are found, do not use until the battery
has been properly repaired or re placed.
2. Clean any oil, grease or dirt from the tool, including
the QCS Sleeve, handles and controls. This aids
inspection and helps pre vent the machine from slip-
ping from your grip.
3. Inspect the electrical tool for the following:
• Proper assembly, maintenance and complete-
ness (See Figures 1-3) .
• Any broken, worn, missing, misaligned or binding
parts.
• Presence and readability of the tool and battery
warning labels.
• The fabric loops are undamaged and stitching is
not torn.
• Foreign material in the QCS that could damage
the electrical tool or interchangeable heads.
• Confirm that the twelve (12) retaining balls in the
QCS coupling are present in all openings and that
there is no damage. Figure 4 shows the inside of a
complete and clean QCS coupling.
Figure 4 – Inside of QCS Coupling
6
• Any other condition which may prevent safe and
normal operation.
If any problems are found, do not use the tool until the
problems have been repaired.
4. Inspect and maintain any other equipment being used
per its instructions to make sure it is functioning prop-
erly. Inspect the interchangeable heads for wear,
deformation or other issues. When inspecting the
mating portion of the QCS coupling on the inter-
changeable heads, dimples in the grooves of the
QCS coupling are normal with use and are not con-
sidered damage ( Figure 5).
Figure 5 – Dimples In QCS Coupling Grooves
Set-Up And Operating
Instructions
Keep your fingers and hands away from the inter-
changeable head during the operating cycle. Your
fingers or hands can be crushed fractured or ampu-
Retaining
tated in the interchangeable head or tool or be -
Balls
tween the interchangeable head, work piece and
other objects.
This tool is not insulated for use on or near ener-
gized conductors. Use of this tool near energized
conductors may lead to electrical shock, causing
severe injury or death.
Large forces are generated during use that can
break or throw parts and cause injury. Keep all
unnecessary personnel away from work area. Stand
clear during use and wear appropriate protective
equipment, including eye protection.
Do not operate the electrical tool without an inter-
changeable head in place/inserts in the inter-
changeable head. This can damage the electrical
WARNING