sYsTEM LAY-OUT

DUKE operator
radio antenna
blinker
Photoelectric cells (external)
Photoelectric cells (internal)
Key selector
114/4,5
327/2,9
66/2,6
80/3,1
Ø 80/3,1
Measurements in mm/inch
T
ECHNICAL fEATUrEs
The DUKE is an irreversible operator complete with mechanical
limit switches and a trafficable cover.
DUKE 110° varying the speed of the opening and closing
movements (opening movement initially slow, then fast; closing
movement initially fast, then slow immediately before shutting).
The DUKE functions as a load-bearing centre hinge, designed
in such a way that the motor can be removed for servicing
purposes without taking down the gate.
The DUKE will comfortably operate gates and doors up to 800
kg in weight and 2 metres in length.
TECHNICAL DATA
Max. leaf length
Max. leaf weight
Average opening time
Max torque
EEC Power supply
Motor capacity
Power absorbed
Capacitor
Normative cycles
EEC Power supply
Motor capacity
Power absorbed
Capacitor
Normative cycles
lubrification
Weight of operator + its foundation box
Noise
Volume
Operating Temperature
1
Protection
* For leaves longer than 2 m it is suggested fitting an electro-lock
240/9,4
Ø 80/3,1
385/15,1
19
19
DUKE
110°
180°
m
3,5*
kg 800 (2 m) - kg 400 (3,5 m)
s.
20
30
Nm
330
230V~ 50/60Hz
W
302
A
1,5
µF
10
n° 8 - 20s/2s
6 - 30s/2s
120V~ 60Hz
W
319
A
3,7
µF
35
n° 10 - 20s/2s
6 - 40s/2s
with grease
kg
21
db
<70
m
0,028
3
°C
-10 ÷ +55°C
iP
67
114/4,5
G
B
35
2