Herunterladen Inhalt Inhalt Diese Seite drucken

Liveviewer; In The Camera Column, Enter The Ip Address Of - Bosch TTM 2104 Serviceanleitung

Vorschau ausblenden Andere Handbücher für TTM 2104:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 4
en
en
46 | TTM 2104/2204 | Calibration (field calibration)
14.2
Permanent.log file
In the browser's address bar, enter the IP address of
the desired module, followed by
2016-08-05T18:26:54.473701Z;2;
error-code: 0x0400030BBB,
id: 3003,
category: Permanent (4),
action: User action - see handbook (3),
EXCLUSIVE, Network connection between satellite
and master not working.
Fig. 34:
Example: Permanent.log file
14.3
XML file
In the browser's address bar, enter the IP address of
the master module, followed by
i
The XML file can only be viewed on the master
Value
Explanation
crossing_status Crossing valid (0) or invalid (1, -1).
crossing_
Indicator for direction of travel.
R Positive value = forward direction
direction
R Negative value = backwards direction
frame_count
Number of images made during the crossing.
The higher the value, the greater the number
of images available for the measurement. A
value over 30 indicates a crossing at 6 km/h
(+/- 1 km/h). A value of >140, somewhat less
than 1 km/h. The slowest possible crossing
has 150 frames.
FL, FR, RL, RR
Designates the particular tire:
R FL = Front Left
R FR = Front Right
R RL = Rear Left
R RR = Rear Right
Left, middle,
Designates the region on the tire:
R Left
right
R Middle
R Right
Result
Indicates the tread depth in mm.
Confidence
Confidence is a trust value. The higher the
number, the greater the probability that the
indicated tread depth is correct.
|
1 691 206 007
2017-06-19
.
/special/permanent.log
.
/special/last-xml-result
14.4

LiveViewer

1. Start LiveViewer.
2. Open the file 'BEST-FRAME.BFD' in the folder
'MASTER/TTM/CAR_RECORD_SETS/TIMESTAMP_
CAR_RECORD_SET/CROSSING_DATA/TIMESTAMP_
TYRE'.
3. In the Camera column, enter the
the desired module.
1
2
3
4
Fig. 35:
Establishing connection to module
1 IP address of module
2 Illumination time
3 Connect button
4 Start button
5 Select image format
4. Enter illumination time (e.g. 10000)
5. Select <Connect>.
 The camera of the selected module is started.
6. Select menu item "Image Format".
7. Select image format "Demosaicing 1 2x2".
Fig. 36:
Connected module
IP address
of
5
Robert Bosch GmbH

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Ttm 2204

Inhaltsverzeichnis