DOFFING
Do not remove the headtop or turn off the air supply until you have
vacated the contaminated area.
1. Lift the Headtop off the head.
2. Turn off the air supply to the V-100E/V-200E unit.
3. Unbuckle the waist belt.
NOTE
If the respirator has been used in an area that has caused it to
become contaminated with a substance requiring special
decontamination procedures it should be placed in a suitable
container and sealed until it can be decontaminated or discarded.

CLEANING INSTRUCTIONS

• Use a clean cloth dampened with a mild solution of water and liquid
household soap.
• Do not use petrol, chlorinated degreasing fluids (such as
trichloroethylene), organic solvents or abrasive cleaning agents to clean
any part of the equipment.
• To disinfect use wipes as detailed in Reference Leaflet.
• Allow product to dry before use.

MAINTENANCE

Maintenance, servicing and repair must only be carried out by properly
trained personnel.
^ Use of unapproved parts or unauthorised modification could
result in danger to life or health and can invalidate any warranty.
If disposal of parts is required this should be undertaken in accordance
with local health and safety and environmental regulations.
WHAT
WHEN
General Inspection
Before use
Monthly if not in regular use
Cleaning
After use
A maintenance record should be kept at the monthly checking stage to
comply with Health and Safety Regulations. This record should be kept for
at least 5 years.
V-100E/V-200E MUFFLER REPLACEMENT - See Fig 2.
FAULT FINDING
Symptom
Possible Cause
No Airflow
1. External air supply turned off
2. Compressed air supply tube
blocked or trapped
3 . Unit defective
Low air flow (whistle
1. Input pressure too low
sounding)
2. Whistle characteristic
3. Aircare air filtration unit
blocked (if used)
4 . Unit defective
Odour Detected
1. Aircare air filtration unit
requires maintenance (if used)
2. External air supply
contaminated
3. Headtop poorly fitted or
damaged
Too much air
Input pressure too high
Insufficient heating or
Input pressure too low
cooling effect

STORAGE AND TRANSPORTATION

These products should be stored in the packaging provided in dry, clean
conditions away from direct sunlight, sources of high temperature, petrol
and solvent vapours. Do not store outside the temperature range -10°C to
+50°C or with humidity above 90%. When stored as stated, the expected
shelf life of the product is 5 years from date of manufacture. The original
packaging is suitable for transporting the product throughout the European
Union.

TECHNICAL SPECIFICATION

(Unless otherwise stated in the Reference Leaflet)
Respiratory Protection
EN14594
Nominal and Assigned Protection Factors: please see relevant Headtop
User Instructions
Inlet Pressure
Pressure Range: 4 - 6 bar
Maximum pressure: 10 bar
Outlet Flow Characteristics
Manufacturers Minimum Design Flow (MMDF) 170 l/min
Maximum flow (V-100E): 495 l/min
Maximum flow (V-200E): 500 l/min
Operating Conditions
5 to +40ºC and <90 % humidity
Weight:
V-100E (with comfort pad and belt) = 650 grams
V-200E (with comfort pad and belt) = 750 grams
Compressed Air Supply Tube (CAST)
Standard Duty to EN14594 'B' and EN270
Maximum length (CAST): 30 metres
Maximum number of in-line couplings: 2
Maximum safe working pressure: 10 bar
Maximum pressure rating: 30 bar
Light Duty to EN14594 'A' and EN1835
Maximum length (CAST): 10 metres
Maximum number of in-line couplings: 1
Maximum safe working pressure: 10 bar
Maximum pressure rating: 20 bar
Remedy
1. Turn on supply
2. Check supply tube
3. Replace unit
1. Adjust air filtration unit or
wall regulator to increase
input pressure (ensuring
pressure within range given
in Technical Specification)
2. Disconnect, then
reconnect the compressed
air supply tube at >4.0 bar
pressure
3. Check Aircare unit
4. Replace unit
1. Check Aircare unit
2. Check quality of external
supply
3. Refit or replace headtop
Adjust air filtration unit or
wall regulator to reduce
input pressure (ensuring
that whistle does not sound)
Adjust air filtration unit or
wall regulator to increase
input pressure (ensuring
pressure within range given
in Technical Specification)
4