OPERATING MODE

● See page 8.
The tool can be handheld or used as fixed
spindle on a tool.
Handheld tool
As the reaction force increases in
proportion to the tightening torque, make
sure that the tool is in perfect working
order and the controller is programmed
correctly, to reduce the risk of injury to
the operator as a result of unexpected
behaviour of the tool.
● Fit the tool with a suitable fastening
accessory, then connect it to the power supply
by means of the controller.
● Select the program and appropriate command
mode on the controller (for a PUSH START
operation: enable the PUSH START command
in the CVIXS controller. To start in lever mode:
disable the PUSH START command).
● Hold the tool by means of the handle and
apply to the fastener to be tightened.
● In PUSH START mode (B), apply axial thrust
with the tool on the fastener to be tightened,
to start the tool.
● In lever mode (A), press the lever to start the
tool.
● For a reverse rotation (C), choose between 3
operating modes parametrisable in the CVIXS
controller:
- Start the tool in unscrewing mode with the
unscrewing button. As long as the button is
activated, the tool unscrews. The lever or
the PUSH START is inoperative.
- Briefly press the inversion button, then
press either on PUSH START or on the
lever to start the tool. To return to the
screwing position, press again on the
inversion button.
- Briefly press the inversion button, then
press either on PUSH START or on the
lever to start the tool. At the next starting,
the tool automatically starts in the tightening
direction.
05/2019

MAINTENANCE INSTRUCTIONS

Maintenance should be performed by qualified
personnel only.
● Prior to any maintenance task:
- disconnect the tool.
- check that the controller is switched off.
- disconnect the cable.
Overhaul and preventive maintenance is
recommended at regular intervals once
per year or after maximum 2,000,000
tightenings depending on which occurs
sooner.
Assembly and disassembly
● When disassembling the tool electronics, take
extra care for the wires when pulling out the
connectors.
● Follow standard engineering practices and
refer to figures/exploded view for the mounting
of component subassemblies.
● Prior to putting the equipment back into
service, check that its main settings have not
been modified and that the safety devices
work properly.
Lubrication
● Do not apply too much grease on gears or
bearings; a thin coat shall be sufficient.
When disposing of components,
lubricants, etc... ensure that the relevant
safety procedures are carried out.
According to Directive 2012/19/
CE concerning Waste Electrical and
Electronic Equipment (WEEE), this
product must be recycled.
● Contact your Desoutter
representative or consult the website
"www. desouttertools.com" to find out
where you can recycle this product.