Herunterladen Inhalt Inhalt Diese Seite drucken

Troubleshooting; Warranty And Service Information; Warranty Terms - Parkside PSH 3 A1 Montage-, Bedienungs- Und Sicherheitshinweise

Vorschau ausblenden Andere Handbücher für PSH 3 A1:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

  • DEUTSCH, seite 29
Troubleshooting / Warranty and service information / Warranty terms

Troubleshooting

Error
The filter does not darken in a
normal way or flickers.
The reaction is slow.
The visibility is poor.
The welding helmet slips.
Warranty and service
information
Creative Marketing Consulting GmbH
warranty
Dear customer, the warranty for this device is 3 years
from the date of purchase. In the event of product
defects, you have legal rights against the retailer of
this product. Your statutory rights are not limited in
any way by our warranty detailed below.

Warranty terms

The warranty period begins on the date of purchase.
Please keep the original receipt in a safe place.
This document is required as your proof of purchase.
270752_Schweisshelm Automatik PSH 3 A1_content_HR_BG.indd 9
Cause
The protector does not darken in
a normal way or flickers.
The arc sensor is not clear.
The welding current is too low.
The ambient temperature is too
low / high.
The sensitivity is too low.
The protector / the protective
screen is dirty.
The protective film on the protec-
tive screen was not removed.
The ambient light is not sufficient. Apply more light to your work
The wrong darkening shade has
been set.
The headband
has been put
5
on incorrectly.
Should this device show any fault in materials or
manufacture within 3 years from the date of pur-
chase, it will be repaired or replaced - at our choice
- by us free of charge. This warranty is conditional
on the defective device and the receipt of purchase
being presented within the 3 year warranty period,
and that there is a brief written description of the
nature of the defect and of the date it arose.
If the defect is covered by our warranty, you will
receive the product which has been repaired or a
new product. A repair or exchange of the device
does not begin a new warranty period.
Solution
Clean the protector or replace it.
Clean the arc sensor's surface.
Set the sensitivity to the maximum
degree.
Only use the welding helmet in
temperatures between -5 °C and
+55 °C.
Set the sensitivity to a higher
setting.
Clean the protector and the pro-
tective screen.
Remove the protective film.
surroundings.
Reset the darkening shade.
Put on the headband
again
5
tighter.
GB
9
27.01.16 11:18

Werbung

Inhaltsverzeichnis
loading