Possible incorrect use
The following restrictions apply to the
unit:
• Do not use for long-term operation
(e.g. continuous recirculation of the wa-
ter in a pond).
• Not suitable for salt water.
• Never use for pumping dirty wa-
ter/waste water.
• Do not connect to the domestic water
supply.
• Not suitable for drinking water.
• Do not use in conjunction with chemi-
cals, foodstuff, easily flammable or ex-
plosive substances.

INSTALLATION AND CONNECTION

N O T E
For permanent installation of the pump,
use flexible compression-proof hoses to
connect it to the pipe network to reduce
the noise of the pump.
N O T E
If the pump is used as a booster pump,
ensure that the max. internal pressure of
6 bar on the pressure side is not exceed-
ed.
• The pump pressure is added to the
pre-pressure.
• Example: Pre-pressure = 1 bar, max.
pressure of the pump = 4.5 bar, total
pressure = 5.5 bar.
16
• Install the pump in a horizontal and
stable position in a dry place.
– For permanent installation of the
pump, ensure that a sufficiently large
collecting basin can be positioned
underneath the discharge screw for
emptying the pump.
• If possible, install the pump in a higher
position than the container/reservoir
from which the water is to be pumped.
If this is not possible, a pressure-proof
valve must be fitted between the pump
and the suction hose.
• Only use vacuum-proof pressure hoses
on the pressure and suction side.
N O T E
OASE recommends: Additionally fasten
the suction hose (e.g. by tying it to a
wooden stake) to relieve the weight of
the hose on the pump.
 B
• Screw a suction and pressure hose
with 25.0 mm internal diameter (1") on-
to the connections.
ProMax Garden Automatic 3500/4000/5000/6000