Robust steel structure on 4 adjustable feet. Exterior and top finish entirely made of stainless steel 18/10.
Stainless steel pan with steel bpttpm in model BS80FE7 - BS8FE7.
-
Stainless steel pan with INOX in model BS80IE7 - BS8IE7.
-
Stainless steel lid, hinge.mounted .
-
-
Hand tilting of the pan.
-
Heating of the pan by means of three heating elements (2900W 240V each), fitted to the bottom of the
pan.
Temperature regulation is possible between 45° and 295°C by means of a thermostat fitted to the switch.
-
A safety thermostat cuts off power supply automatically in case of failure (eg. breaking of thermostat ).
-
-
A green signal lamp lights when the appliance is on.
An orange signal lamp lights when one of the heating elements is on.
-
-
Filling of the pan by means of a tap placed on the front panel.

1.4. LAWS, TECHNICAL PRESCRIPTIONS AND DIRECTIVES

-
When installing the appliance it is necessary to follow and comply with the following regulations:
-
current regulations on the matter;
-
any hygienic-sanitary regulations concerning cooking environments;
-
municipal and/or territorial building regulations and fire prevention prescriptions;
-
current accident prevention guidelines;
-
electricity board regulations concerning safety;
-
the regulations of the electrical power supply company or agency;
-
any other local prescriptions.

1.5. SPECIAL REQUIREMENTS FOR THE INSTALLATION SITE

-
The room in which the appliance is to operate must be well ventilated.
-
In addition, it is good policy to locate the appliance under an extractor hood so that cooking vapours can
be removed rapidly and continuously.
-
Current regulations require the installation of a multiple pole switch between the appliance and the
electrical power supply; the switch must have a contact gap of least 3 mm on each pole.
-
This appliance requires one water connection. The line must be fitted with an on-off valve.
Warning! :
The electrical isolating switch and the water shutoff valves must both be located near
to the appliance, within easy reach for the user.