vibrate, causing the blade to break more
easily.
Let the saw do the job. Do not put undue
pressure on the circular saw.
5. MAINTENANCE
Make sure that the machine is not live
when carrying out maintenance work on
the motor.
The machines have been designed to operate
over a long period of time with a minimum of
maintenance. Continuous satisfactory operation
depends upon proper machine care and regular
cleaning.
Troubleshooting
Below we have listed a few probable causes and
solutions to which you can refer if your circular
saw does not function properly.
1. The temperature of the electric motor ex­
ceeds 70°C.
The motor has been overloaded by working it
too hard.
Cut more slowly and allow the motor to
cool down.
The motor is defective.
Please contact the service address on
the warranty card.
2. The tool does not work when switched on.
Damaged cord and/or plug.
Check cord and/or plug.
Defective switch.
Please contact the service address on
the warranty card.
3. When cutting it is very difficult to move the
work forward in a straight line and the cut
is not clean.
The blade is bent or blunt.
Replace the blade.
4. The circular saw makes a lot of noise and/
or does not run smoothly.
The carbon brushes are worn.
Please contact the service address on
the warranty card.
Ferm
Cleaning
Keep the ventilation slots of the machine clean to
prevent overheating of the engine.
Regularly clean the machine housing with a
soft cloth, preferably after each use. Keep the
ventilation slots free from dust and dirt.
If the dirt does not come off use a soft cloth
moistened with soapy water. Never use solvents
such as petrol, alcohol, ammonia water, etc.
These solvents may damage the plastic parts.
Replacing hte carbon brushes
Remove the screws (17).
Withdraw the carbon brushes (18) from the
circular handsaw and inspect them for wear.
Place the carbon brushes back in the brush
holders provided.
Check that the copper contact on the carbon
brushes makes good contact with the copper
part in the brush holder.
Replace the screws (17) and tighten them
firmly.
Frequent use will cause the carbon
brushes to wear down. Regular
inspection, after every 30 hours of use,
is essential. If the brushes have worn
down to less than 4 mm, replace.
Lubrication
The machine requires no additional lubrication.
Faults
Should a fault occur, e.g. after wear of a part,
please contact the service address on the
warranty card. In the back of this manual you find
an exploded view showing the parts that can be
ordered.
Environment
To prevent damage during transport, the
appliance is delivered in a solid packaging which
consists largely of reusable material. Therefore
please make use of options for recycling the
packaging.
Faulty and/or discarded electrical or
electronic apparatus have to be
collected at the appropriate recycling
locations.
Warranty
The warranty conditions can be found on the
separately enclosed warranty card.
EN