BATTERY

If supplied, the Pb-Acid (if not dry charged) or gel bat-
teries are ready to be installed:
Positive pole - red
Negative pole - black.
5.2.3

BATTERY CHARGER

If supplied, refer to the corresponding booklet.
5.3

BATTERY CHARGER CONFIGURATION

We recommend to call the assistance centre or
a technician if you have problems with the setting
given.
The machine is equipped with a battery charger con-
figurated for PB-Acid batteries
If the operator whish to use GEL / AFGM batteries, it
is necessary change the battery charger settings as
follows:
DISPLAY OF THE BATTERY CHARGER SETTINGS
The battery charger settings are shown by the blink-
ing of the LED indicator when the battery charger is
switching on:
- the RED LED indicator ( Photo I - 2 ) flashes 2 times
= the battery charger is set for PB-Acid batteries
- the GREEN LED indicator ( Photo I - 3 ) flashes 2
times = the battery charger is set for GEL batteries
The battery charger settings will be displayed even if
batteries are not connected.
DIP-SWITCH CONFIGURATION FOR BATTERY
CHARGER CBHD2 24V 20A
To set the charging curve type for Pb-Acid or GEL/
AGM batteries it is necessary to operate on the dip-
switches placed inside the battery charger ( Photo
I -4 ).
The dip-switches for the setting of the charging curve
are on the control card ( Photo I - 4 ) that is placed
behind the lower panel of the battery charger ( Photo
I - 1 ). It is also possible to reach the dip-switches by
removing the plastic cap ( Photo I - 5 ).
For the setting of the charging curve it is necessary to
operate on the dip-switches of the group indicated
as SW1 ( Photo I - 6 ), placing them as shown in the
table ( Photo I - 6) at page 7.
NOTE: The dip-switches of the group indicated as
SW2
must always be set in the OFF position.
5.4

ACCESSORIES

Your machine supplier can provide a complete and
updated list of all available accessories, such as
brushes, pad drivers, disks, etc.

6. INSTALLATION INFORMATION

6.1

BATTERY PREPARATION

The technical features of the batteries used must
match those indicated in the technical features sec-
tion. Using different batteries may cause serious
damage to the machine or may require them to be
charged more frequently.
During installation or when performing any type of
battery maintenance, the operator must be equipped
with adequate safety accessories to prevent acci-
dents. Work far from open flames, do not short-circuit
the battery poles, do not generate sparks and do not
smoke.
The batteries are normally supplied full of acid solu-
tion (for the Pb-Acid type) and ready for use. In any
case, follow the steps indicated in the manual sup-
plied with the battery and carefully follow the instruc-
tions regarding safety and operating procedures.
6.2
BATTERY INSTALLATION AND PREPARA-
TION
These operations must be carried out by special-
ised personnel.
Make sure the two tanks are empty. If not, empty
them in accordance with the specific procedure.
Lift the recovery tank by 90°, making sure it is stable
in that position. This provides access to the battery
compartment from the top.
Disconnect the Anderson connector of the battery
wiring from the Anderson connector of the machine
wiring. Always hold the connectors with the hands
and never pull on the cables.
Attach the battery wiring to the battery, con-
necting the terminals only on the poles marked
with the same symbol (red wiring "+", black wiring
"-")! A battery short-circuit may cause an explo-
sion!
Run the cables toward the wiring outlet opening
(on one side of the box, only for Pb-Acid batteries),
tighten the terminals at the poles and cover them
with Vaseline.
35