INTRODUCTION:
Whirlpool baths must be installed by trained personnel able to
demonstrate to the relevant authorities their knowledge and
ability in the application of health and safety regulations i.e.
electricity and water supplies and waste water disposal. The
manufacturer provides training for technical assistance staff and
therefore you are advised to contact an authorised technical
assistance centre for the purposes of installation.
This symbol indicates important product instructions or
important safety information.
INSTALLATION:
IMPORTANT!
Before you start to assemble and install the product, carefully
read through all the instructions. Unpack the components and
check that nothing is missing and that there are no damaged or
faulty components, remove the transparent protective film.
All components requiring maintenance (e.g. pump, electrical
components, etc) must remain accessible once final installation
is complete.
Do not support the bath using the hoses during transport.
N.B.: This product is designed for installation on finished walls
and floors.
Warranty claims must be produced with the purchase invoice
and the product assembling instructions.
The drawings and illustrations in this manual are provided for
information purposes only.
The manufacturer reserves the right to make changes and
improvements without prior notice.
INSTALLATION OF BATH WITH FRAME:
Follow the sequence of drawings given in this manual very
carefully when installing a bath with frame.
INSTALLATION OF ENCLOSED BATH:
Before building the enclosing walls, it is best to position the
bath and make the required connections. The wall can extend
inwards under the lip of the bath by not more than 1.5 cm. The
drain must be connected in such a way that the bath can be
pulled out of the enclosure for maintenance, when necessary.
To facilitate this operation do NOT fix enclosed type baths to
the floor. In this case, fix the bath by applying silicone on all four
sides (see siliconing illustration on page 38).
Inspection panel required.
(I)
OPERATING TEST:
An operating test must be performed following installation.
Check that the bath is clean.
1
2
3
Fill the bath with water at an infeed temperature of 40°C (± 5°C)
up to a level above the highest nozzle to allow the system to
function.Switch on the system and run it for 10 minutes. Switch
OFF the whirlpool function but do not empty the bath and after
10 minutes check all the hoses, couplings, etc. for any leaks.
The test should be repeated following any adjustments or
substitutions. Backflow of water towards the mains water supply
must be avoided to ensure conformity with EN 1717 when filling
the bath. Therefore if the taps are fitted so that the water fills
the bath from above the top of the bath then the taps must be
positioned (at least in terms of height) in accordance with the
diagrams shown from page 6.
If the system involving a combined water inlet and overflow
outlet is used to fill the bath, a water outlet spout consisting of
a non-return valve (not supplied) must be fitted between the
combined tap water inlet point and the delivery system located
on the discharge column.
CLEANING AND DISINFECTING:
During use, small organic particles are deposited in the whirlpool
pipes and if not treated may lead to proliferation of bacteria in
the system. For perfect hygiene, you should treat the system
with specific products available from our Service Centres (see
updated list on our site www.novellini.com under the heading
"Service") or dealers specialising in products for whirlpool baths.
For temporary treatment you can use a liquid disinfectant
(eg. Dettol). How to clean the bath. You should also perform a
specific treatment if the bath is left unused for long periods. If
the bath is used by more than one person consecutively, you are
recommended to disinfect after each cycle.
You should never use or take a bath in the water used for
disinfecting.
The first time you disinfect, fill the disinfectant tank with a
specific product or Dettol. Tank capacity 1 litre.
ADJUSTING JET NOZZLES:
Turn the jet nozzles (C) as required. The nozzles can be turned
in any direction. Make sure that the nozzles are not clogged and
are not directed upwards (otherwise water will be splashed out
of the tub when the system is switched on). Fill the tub until the
water is well over the level of the jet nozzles (see illustration).
After getting into the bath, the water level must be as shown
in the illustration, otherwise the jets system may not start. The
system features a level sensor which prevents the jets from
switching on if there isn't enough water in the bath. When the
jets system is on, do not use foaming agents such as bubble
baths, soap, etc.
HOW TO USE YOUR WHIRLPOOL BATH CORRECTLY:
The benefits of a whirlpool massage:
The swirling water of a whirlpool bath is naturally soothing and
offers many therapeutic benefits. In spas, hydrotherapy is used
to stimulate blood circulation, relax muscles and restore tone to
the skin. Basically, it consists in injecting air into controlled jets of