Error codes

Use the list below to check the meaning of the error codes displayed in the error code display window.
Error code
Meaning
10, 11, 12, 13
The fan is not running.
20
The lamp is out of order. (The
lamp does not light up.)
21
The lamp is not installed.
22
The cooling fan for the lamp is out
of order.
23
Temperature of the lamp power is
too high.
Temperature of the lamp housing
24
is too high.
27
Temperature around the projector
is too high.
75
Temperature around the projector
is too low.
1A
The front lens cover is detached.
1B
The rear lamp cover is detached.
Other error codes
8
(EN)
Remedy
Consult qualified service personnel.
Adjust the room temperature so that the temperature around the
projector becomes within acceptable range (10°C to 35°C (50°F
to 95°F)). Leave the projector for about one hour without
ventilation holes blocked to let the temperature go down. When
the lamp does not light up even if the room temperature becomes
within acceptable range, consult qualified service personnel.
Adjust the room temperature so that the temperature around the
projector becomes within acceptable range (10°C to 35°C (50°F
to 95°F)). (No picture may appear when the temperature around
the projector is too high.)
Warm up the inside of the projector for a while with the lamp lit.
The picture will appear as the temperature around the projector is
adjusted to be in acceptable range (10°C to 35°C (50°F to 95°F)).
Close the lens cover securely.
Close the internal lamp cover securely.
Consult qualified service personnel.