Herunterladen Inhalt Inhalt Diese Seite drucken

Line-Fed Glass Break Detector; Ims-Rm Relay Module (Optional) - Bosch ISP-EMIL-120 Installationsanleitung

Expansion modules
Vorschau ausblenden Andere Handbücher für ISP-EMIL-120:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 13
Expansion modules
Element Description
8
9
10
5.4

Line-fed glass break detector

4
Element Description
1
2
5.5

IMS-RM relay module (optional)

4
Bosch Security Systems B.V.
Blocklock for primary line (wire color : 39 = black, 40
= blue)
Resistors (EOL 1 and EOL 2):
EOL 1 = 3k92 and EOL 2 = 12k1 for ISP-EMIL-120
and ISP-PCBA-EMIL
EOL 1 and EOL 2 = 4k7 for ISP-EMIL-3RDP
E.g. door contact
Resistor (EOL):
12k1 for ISP-EMIL-120 and ISP-PCBA-EMIL
4k7 for ISP-EMIL-3RDP
E.g. bolt contact
Resistor (EOL):
12k1 for ISP-EMIL-120 and ISP-PCBA-EMIL
4k7 for ISP-EMIL-3RDP
Refer to graphic 9 in chapter Graphics, page 4.
Incoming and outgoing LSNs, can be exchanged.
Route the cable shield both ways.
4
A maximum of 20 glass break detectors can be
connected to a primary line PL 5 and PL 6 (VdS).
Loop in terminal resistance 12k1 after the last
4
detector.
A maximum of 3 detectors are supported in the event
of an alarm. Standby current: < 1 µA, max. alarm
current: 4 mA at 6 V.
Refer to graphic 10 in chapter Graphics, page 4.
Connection | en