Herunterladen Inhalt Inhalt Diese Seite drucken

Mounting The Inverter; Connecting The Inverter; General Instructions - Dometic MSI912 Montage- Und Bedienungsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 35

Connecting the inverter

8.3

Mounting the inverter

➤ Hold the inverter against the installation location and mark the fastening points
(fig. 4 A, page 4).
➤ Attach the inverter using your chosen fastening method (fig. 4 B, page 4).
9
Connecting the inverter
9.1

General instructions

!
WARNING!
• The inverter may only be connected by a qualified workshop. The
following information is intended for technicians who are familiar
with the guidelines and safety precautions to be applied.
• Never use the inverter on vehicles where the positive terminal of the
battery is connected to the chassis.
• If you do not fit a fuse to the positive cable, the cables can over-
load, which might result in a fire.
• Reversed polarity can damage the inverter.
• MSI900, MSI1300, MSI1800 only: The inverter should not be
used to connect to a ring main, it must only be used to power individ-
ual appliances that are plugged into the inverter outlet either directly
or using a purpose-made, moulded extension lead
• When installed in vehicles or boats, the inverter must be connected to the chassis
or earth.
• When setting up a socket distribution circuit (mains setup), comply with the appli-
cable regulations.
• Only use copper cables.
• Keep the cables as short as possible (< 1.8 m).
18
SinePower
EN

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis