The scope of supply includes an A&K Müller solenoid valve (Dn 7 50.007 .100 bi).
3. Functional sequence:
1.
Usage
2.
Flushing 2 15s (adjustable).
3.
Idle interval after flushing (after-running water), adaptive approx. 6-10 s.
4.
Hygiene flushing prevents the siphon from drying out.
5.
No flushing if the bowl is blocked (overflow protection).
6.Start of stadium mode:
If > 5 uses within 3 minutes = 1 flush / minute
Stop stadium mode:
No use within 1 minute = normal operation.
4. Installation and start-up:
Install the HF urinal control. To install the sensor, attach the enclosed adhesive compound onto the complete
rear of the sensor. Please note the arrow direction. The following figures clearly illustrate the planned
attachment area for the sensor on the respective urinal.The area must be grease-free and dry, in order to ensure
optimum fixing of the sensor. Now firmly press the sensor on the ceramic and fix it for approx. 20 seconds.
Type : Kermag Renova No. 1 Plan
Approx. 5
cm
Sequence
046 10/2011
GB S 01 Operating instructions urinal flushing system
Type: VITRA Matrix
*Approx. 5 cm
*
Sequence
5/12
HEWI | 7