5.2 Electrical connection

Wire in the apparatus according to the electrical supply required by the actuator (see label on product),
following the table below.
230Vac Supply
1
Blue
2
Black
3
Brown
Electric 230Vac wiring
1
2
3

5.3 Operating test

Press the control button and close the window, checking that:
a. The window is completely closed. If it is not, check that the gap between the window and the frame is bigger
than or equal to 0 mm. If necessary, insert spacers so as to obtain the correct gap.
b. The chain is perfectly vertical to the window frame. If necessary adjust the fixing bracket by using the screws
and slots.
Having reached the correct closing position, press the control button and open the window in order to check
that the actuator runs freely over the full travel set up.
Having achieved the required opening run, press the control button again to close the window. Once the window
has completely closed, check that the screws, supports and fixings are tightened correctly, and that the seals
are sufficiently compressed.
Neutral / Common
Phase / Open
Phase / Closed
1
2
1
2
3
N
110/230V~ 50/60Hz F
Installation completed
CAREFUL!! - after installation the cover must be closed.
24Vdc supply
1
Blue
2
Brown
Electric 24Vdc wiring
1
2
N
+
110/230V~ 50/60Hz F
24 Vdc
-
Positive
Negative
+
24 Vdc
-
13