12. SPECIFICATIONS
Input
– Slow
– Medium
– Fast
– Engine Start
Output
– Slow
– Medium
– Fast
– Engine Start
Weight
Reverse Polarity Protection

13. TROUBLESHOOTING AND ERROR CODES

Error Codes
CODE
The battery voltage is still under
10V (for a 12V battery) or 5V
F01
(for a 6V battery) after 2 hours of
charging.
The charger cannot desulfate
F02
the battery.
The battery was unable to reach
the "full charged" voltage.
F03
The connections to the battery
F04
are reversed.
The charger was unable to
keep the battery fully charged in
maintain mode.
F05
The charger detected that the
battery may be getting too hot
F06
(thermal runaway).
If you get an error code, check the connections and settings and/or replace the battery.
Troubleshooting
PROBLEM
CONNECTED
not on.
230V~50Hz
.86A
1.15A
2.85A
8.5A
6/12V
6/12V
6/12V
12V
12.8 lbs. (5.82 kg)
Yes
DESCRIPTION
POSSIBLE CAUSE
The battery is not connected
LED is
correctly.
Battery voltage is at zero volts.
Input fuse is bad.
Output breaker is bad.
3A
5A
20A 105 seconds on / 5A 180 seconds on
90A Peak 150A @ 0V
Could be caused by trying to charge a 6 volt
battery on the 12 volt setting, or the battery
could be bad; have it checked or replaced.
The battery could not be desulfated; have it
checked or replaced.
Could be caused by trying to charge a large
battery or bank of batteries on too low of a
current setting, or the battery may have a
shorted cell. Try again with a higher current
setting, or have the battery checked or
replaced.
The battery is connected backwards. Unplug
the charger and reverse the connections to
the battery.
The battery won't hold a charge. Could be
caused by a drain on the battery, or the battery
could be bad. Make sure there are no loads
on the battery. If there are, remove them. If
there are none, have the battery checked or
replaced.
The charger automatically shuts the current off
if it detects the battery may be getting too hot
or the battery may have a shorted cell. Have
the battery checked or replaced.
9
CAUSE
SOLUTION
Check for proper connection to
the battery.
Turn off everything in the car
and try to connect again.
Replace the fuse (5 Amp fuse).
Push button to reset the breaker.