This unit supports the DMX protocol extension RDM. RDM (Remote Device Management) is a new, open and bi-direc-
tional protocol standard for DMX-512 controlled units. The protocol allows to receive status information about a unit or
to change configurations on a unit. Prerequisite for this function being an RDM compatible controller. E.g. Oase WECS
1024.
RDM (Remote Device Management) is a new, open and bi-directional protocol standard for DMX-controlled devices.
The permanently transmitted DMX data flow briefly pauses (several milliseconds), and an RDM data package (mes-
sage) is sent directly to a subscriber. The subscriber evaluates the information in the data package and sends an
answer (semi-duplex) on the same line. Targeted polling to a subscriber via its UID (Unique ID) prevents several sub-
scribers from answering simultaneously.
RDM parameter overview:
General parameters
COMMS_STATUS
STATUS_MESSAGES
STATUS_ID_DESCRIPTION
SUPPORTED_PARAMETERS
PARAMETER_DESCRIPTION
DEVICE_INFO
PRODUCT_DETAIL_ID_LIST
DEVICE_MODEL_DESCRIPTION
MANUFACTURER_LABEL
DEVICE_LABEL
SOFTWARE_VERSION_LABEL
DMX_PERSONALITY
DMX_START_ADDRESS
SENSOR_DEFINITION
SENSOR_VALUE
RECORD_SENSORS
IDENTIFY_DEVICE
RESET_DEVICE
Specific parameters
Curve X1
Curve Y1
Curve X2
Curve Y2
Curve X3
Curve Y3
Error monitoring
Runtime hours
Startup counter
Control mode
Config mode
GET
SET
Description
CMD
CMD
*
*
Shows general status information of the bus interface
*
Used to manage status messages
*
*
RDM parameter overview
*
Description of all parameters
*
Brief overview of the most important features
*
Additional feature
*
Type designation
*
Manufacturer name
*
*
Labelling field
*
Version number of the firmware
*
*
Operating behaviour (currently the setting cannot be changed)
*
*
Reading and setting the DMX start address
*
Sensor information
*
*
Sensor value
Sensor 1 = „TempErrCount", temperature error counter
Sensor 2 = „MotorFailureCount" motor failure counter
Sensor 3 = „ActualSpeed", current actual speed
Sensor 4 = „NominalSpeed", current setpoint speed
Sensor 5 = „PWM", current PWM value
Sensor 6 = „Temp", current operating temperature
*
Buffering the sensor value
*
*
0 = Normal operation,
1 = Pump will switch on and off again in short intervals. This function is helpful to
identify the unit in the field.
*
Executes a reset.
1 = Warm start / 255 = Cold start
GET
SET
Description
CMD
CMD
*
Support value 1 of the stored pump characteristic curve
*
*
Support value 2 of the stored pump characteristic curve
*
*
Support value 3 of the stored pump characteristic curve
*
*
Only for service purposes
*
Operating hour counter for the running period
*
Startup counter
*
Only for service purposes
*
Only for service purposes