Addressing via DMX
DMX (Digital Multiplex) is a standardised digital transmission protocol used in stage and event equipment as well as in
many Oase components.
The DMX Channel and the mode can be changed by means of a DMX controller from OASE. Read the corresponding
operating instructions.
Description
Serial No. (SN)
Manufacturer ID
Version No.
DMX channel (1 to 511)
Mode
Channel assignment information
For the functions, the unit uses two channels. The first DMX channel is defined with the the OASE DMX control unit.
The first possible value is 1.
The last possible value is 511.
Channel
DMX-Channel + 0
DMX-Channel + 1
Information about show programming
The pump may only be switched on max. 1 x per minute.
Allow at least 10 seconds between switching off and switching on the pump again.
Switching on the pump via DMX
Channel
DMX channel + 1
DMX channel + 0
Waiting time 1-3 seconds
DMX channel + 1
Switching off the pump via DMX
Channel
DMX channel + 1
DMX channel + 0
14
Value
Enter the unit serial number. The serial number is in-
dicated on the type plate
.
161
1
Define the DMX channel. The factory-set channel is
indicated on the type plate
.
1 = define the first DMX channel
Description
Pump OFF
Control mode (please do not use)
Speed Control
Speed Control
Charakteristic line compensation
Free
Error Reset
Default value speed
Description
Pump rotational speed set to minimum
Control mode ON
Effect
Description
Pump rotational speed set to minimum
Pump OFF
Values
0 ... 10
11 ... 49
50 ... 99
100 ... 149
150 ... 239
240 ... 255
0 ... 255
Values
0
50 ... 99
1 ... 255
Values
0
0 ... 10