Supplied accessories
Screw <4>
(M4×10)
Nut <4>
(M4)
Instructions and License List (DVD),
Quick Reference, Installation Instructions
* Wiring are not included (fi eld supplied item).
Dimensions
280
LAN terminal
Storage door
Push lightly to open or close.
Symbols on the controller
This symbol refers to "Protective earth".
Caution for Network Connection
 Connecting to Internet will enable you to operate the unit
and check the status using a PC from a remote location.
 When connecting to Internet, implement security
measures against illegal access from outside.
For detailed connection and setup method, consult the
network administrator.
Mounting
 Design Control Box  Mounting Position
255 (Screw hole pitch)
242 (Hole of the control box)
Screw hole φ5
To ensure proper airfl ow (for heat dissipation) inside the control
box, provide vents (slits, etc.) both on the upper part and lower
part (or bottom side) of the right and left sides.
• Do not allow the temperature inside the control box to exceed 40 °C.
• Be careful not to block the above vents.
< >: Number of pieces
Washer <4>
Clamper <4>
(Part Names)
20
Power
indicator
Illuminates at
power-on.
USB terminal
100
100
or more
or more

Installation Precautions

 Installation Location
 Avoid the following locations for installation.
• Under direct sunlight
• Location near heat source
• Location where the controller will be splashed with water or
affected by dampness or humidity
• Uneven surface
• Location that is subject to excessive vibration or physical impacts.
(Fixing screws may come off, and the controller may drop.)
 Install the controller vertically to the fl oor.
 Install the controller at a location with suitable
temperature and humidity for using.
 Do not install controller at the locations with the
85
equipment (medical equipment, etc.) which generates
the high-frequency emissions.
(It may interfere with the equipment and may cause
accidents due to malfunction.)
 Install at least 1 m away from TV, radio, PC. etc.
(To prevent fuzzy images or noise)
 General Precautions on Wiring
 Regulations on wire diameters differ from locality to
locality.
For fi eld wiring rules, please refer to your LOCAL
(mm)
ELECTRICAL CODES before beginning.
You must ensure that installation complies with all
relevant rules and regulations.
 Use the fi eld supplied wiring with at least 1 mm in
thickness of insulation part including the sheath.
 Connect all wiring tightly to prevent the terminal
board from loosening when the wiring connection
part is pulled by an external force. (Otherwise, fi re or
overheating may occur.)
 Using putty (fi eld supplied item), etc., fi ll the hole of the
control box through which the wiring passes.
 Do not pass the power supply wiring and other wirings
through the same conduit. Keep as long a distance as
possible between them to alleviate the infl uence of noise.
 Do not run the power supply wiring and other wiring in
the same conduit or bundle them together.
(An operational error from noise may occur.)
 Do not bury the wiring in the ground.
 How to Mount (Control Box)
Control box
2. Install to the control box
using the supplied screws,
nuts and washers.
150
Embed into the
or more
control box.
50
or more
1. Remove the
panel-fi xing
screw and
panel (to the
upper side).
100
or more
(mm)
Panel-fi xing
screw
M3×6 <2>
3
< >: Number of pieces
Screw (supplied)
Control box
M4×10 <4>
3. Using the panel-fi xing screw, install
the panel to the original position
(from the upper side).
Nut (supplied)
M4<4>
Washer
(Supplied) <4>