  • DEUTSCH, seite 50
Troubleshooting / Helpful Informations
Is it okay?
The TIMER lamp blinks
How to self diagnose
Press
1
5 seconds
When the indoor unit gives off a continuous "Beep, Beep,
2
Beep, Beep" sound, slowly and repeteadly press
Inform your dealer on the displayed 3 alphanumeric digits.
DISPLAYED ALPHANUMERIC DIGITS
H
The H and F (followed by 2 numerals)
F
represent different sets of abnormalities.
Press
for 5 seconds, using the remote
control select and operate the Heating • Cooling • Dry • Air circulation modes. (There will be
"Beep, Beep, Beep, Beep" sound to confirm the command is received).
When the remote control is not
available and the batteries are out.
It is still possible for emergency operations. In this case,
the unit will operate on the default temperature of 25°C.
Adjustment to the default temperature is not allowed.
1
Switch on the power supply
2
Press the auto operation button.
To stop operation, press the button once more.
Placing things around the indoor unit:
Allow a lot of spacing if you wish to place things around the indoor unit.
If tall furniture are placed near the unit, it may hinder the air flow which will reduce the efficiency of the unit.
When the unit is not operated for an extended period of time:
Operate the AIR CIRCULATION
mode for 2 to 3 hours
(To dry the interior sections of the
indoor unit)
24

Self diagnosis

for
3 alphanumeric digits will appear on the
remote control display.
When H33, H36 and H37 are displayed,
you must not operate until repairs have
been done.
H36 : Heating • Air circulation
H37 : Cooling • Dry • Air circulation

Helpful Information

Auto operation
button
Stop the operations
and switch off the
power supply.
Consult your dealer immediately
Notify them of all abnormalities.
You can self diagnose using the remote control.
Follow the instructions below. After confirmation,
stop all operations and switch off the power supply.
"Beep, Beep,
Beep, Beep"
When there is a power failure
During operation:
All operations stopped. When power supply is restored,
run operations all over again.
During preset timer mode:
The timer mode is cancelled. (The indoor unit TIMER
lamp will be off) When power supply is restored, reset
TIMER once again.
When there are thunders in the vicinity:
To avoid lightning strikes, stop all operations and switch
off the power supply. (To protect the air conditioner)
Remove all batteries from the
remote control.
(To prevent electrolyte leakage)