Flow diagram

(see page 39)
Spare parts (see page 40)
Fault
Insufficient water
Crossflow, hot water being forced
into cold water pipe, or vice versa,
when mixer is closed
Spout temperature does not cor-
respond with temperature set
Temperature regulation not possible
Safety stop button not operating
The mixer does not start or stop
English
Cause
- Supply pressure inadequate
- Regulator filter dirty
- Shower filter seal dirty
- Backflow preventers dirty or leaking - Clean backflow preventers, ex-
- Thermostat has not been adjusted
- Hot water temperature too low
- Temperature regulator dirty or calci-
fied
- For new installations: basic body
incorrectly connected (should be:
cold right, hot left) or installed with
180º rotation
- Spring defective
- push button calcified / contami-
nated
- Battery is drained
- Electronioc, switch or cable fault
Assembly see page 28
Test certificate (see page 40)
Cleaning
see enclosed brochure
Remedy
- Check water pressure (If a pump
has been installed check to see if
the pump is working).
- Clean filter in front of the mixer and
on the MTC-thermo cartridge
- Clean filter seal between shower
and hose
change if necessary
- Adjust thermostat
- Increase hot water temperature to
42 ºC to 65 ºC
- Clean temperature regulator, ex-
change if necessary
- Install function block turned through
180º
- Clean spring and/or button, ex-
change if necessary
- Exchange battery
- Exchange electronic