Safety Notes
Gloves should be worn during installation to prevent
crushing and cutting injuries.
The hot and cold supplies must be of equal pres-
sures.
Only dishwashers and washing machines certified
with the DVGW emblem may be connected to the
appliance connection valve without an additional
fuse. If no consumer is connected to the appliance
connection valve, it must be plugged.

Installation Instructions

• Prior to installation, inspect the product for transport
damages. After it has been installed, no transport or
surface damage will be honoured.
• The pipes and the fixture must be installed, flushed
and tested as per the applicable standards.
• The plumbing codes applicable in the respective
countries must be observed.
Technical Data
Operating pressure:
Recommended operating pressure:
Test pressure:
(1 MPa = 10 bar = 147 PSI)
Hot water temperature:
Recommended hot water temp.:
Thermal disinfection:
The product is exclusively designed for drinking water!
Fault
Insufficient water
Mixer stiff
Mixer dripping
Water escaping in area of swivel
spout
Water escaping at the threaded base - connection hoses not completely
Hot water temperature too low
4
English
max. 1 MPa
0,1 - 0,5 MPa
1,6 MPa
max. 70°C
65°C
max. 70°C / 4 min
Cause
- Aerator calcified, dirty
- Cartridge defective, calcified
- Cartridge defective
- O-ring defective
screwed into basic body
- O-ring at the connection hose defec-
tive.
- Hot water limiter incorrectly set
Assembly see page 32
Symbol description
Do not use silicone containing acetic acid!
Adjustment (see page 36)
To adjust the hot water limiter. Using a hot
water limiter in combination with a continu-
ous flow water heater is not recommended.
Dimensions
(see page 31)

Flow diagram

(see page 31)
Rate of flow mixer
Rate of flow stop valve
Spare parts
(see page 38)
Operation (see page 37)
Hansgrohe recommends not to use as drink-
ing water the first half liter of water drawn in
the morning or after a prolonged period of
non-use.
Cleaning
(see page 39)
Remedy
- Clean aerator, replace as necessary
- Exchange cartridge
- Exchange cartridge
- Exchange O-ring
- Tighten connection hoses by hand
- Exchange O-ring
- Set hot water limiter