Herunterladen Inhalt Inhalt Diese Seite drucken

Seal The Case; Check The Operation Of The Loaded Camera; Perform The Final Checks; Visual Inspection - Olympus PT-E06 Bedienungsanleitung

Unterwassergehäuse für digitalkamera e-620
Vorschau ausblenden Andere Handbücher für PT-E06:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 86

Seal the Case

1 Close the rear lid gently (so that the O-rings do not slip
out of the grooves).
2 Turn the open/close dial clockwise.
• The Case is sealed when the position of the slide lock
is at the top.
CAUTION:
If the open/close dial is not fully turned, the Case will not be sealed airtight and water leakage may occur.

Check the operation of the loaded camera

After sealing the Case, check that the camera functions normally.
• Operate the power switch lever on the Case and confirm that the camera can be turned ON/OFF.
• Turn the mode dial knob on the Case and confirm that the camera mode switches properly.
• Operate the shutter lever on the Case and confirm that the camera shutter is released.
• Operate the zoom dial on the Case and confirm that the camera's lens is controlled.
• Operate other control buttons on the Case and confirm that the camera functions properly as intended.

Perform the final checks

Visual Inspection

After closing the case tightly, check the seal between the front and rear lids and the connection between
the port and case to make sure the O-rings are not twisted, that they sit properly in the grooves, and that
no foreign matter has been caught between the two parts.
CAUTION:
Hair, fiber, and other narrow items are not very apparent, but they may cause entry of water, therefore special
attention is required.
En
EN 18

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis