PREPARATIONS

3.1
Removing the packaging
1. Remove packaging from the heater.
3.2
Installation
1. Make sure that the heater has a stable
set-up.
The heater can be positioned both
horizontally and vertically (blowing up
or down).
Horizontally: a minimum of 0.5 m
above the floor.
Vertically blowing down: a
minimum of 1.4 m above the
floor.
Vertically blowing up: a minimum
of 1.4 m below the ceiling.
The position of the gas regulator
block depends on the heater set-up,
see fig. 6.
2. Hang the heater on the suspension eyes.
Warning
The heater is suited for a gas
pressure of 50 mbar maximum.
When connecting to a higher gas
pressure, a pre-pressure regulator
must be included in the gas pipe, see
fig. 7 (B).
3. Fit a gas cock with an internal
screwthread of 1/2" to the gas inlet of the
heater, see fig. 7 (A).
4. Connect the heater to the gas supply.
Warning
The heater may only be installed by
suitably authorised people in
accordance with the local standards.
5. Shut the gas cock off and place the gas
pipe under pressure.
16
6. Check the burner pressure.
7. To connect an outside-air suction device
to the combustion air fan inlet, see
chapter 9.
8. If the heater is provided with a room
thermostat or time clock, connect it to the
appropriate connection (E) of the
operating panel (fig. 5). As standard, this
connection is provided with a plug to
which the contacts are connected.
9. Insert the plug in the socket.
3.3
1. Check if the heater is correctly adjusted
for the locally-supplied gas (consult the
dealer).
3.4
Heat:
1. Open the gas cock.
2. Switch the selector switch (D) to heat,
see fig. 5.
Ventilate:
1. Switch the selector switch (D) to
ventilate, see fig. 5.
4
4.1
40.020.948 - rev. 04 - 2011
Warning
This check may only be performed by
a suitably authorised person.
The toestellen are adjusted and
regulated for use on natural gas G25
(I2L).
If the yellow control light of the burner
automat is lit, the plug in the socket
must be reversed.
The plug must always be accessible.

Preparing for start-up

Starting up

USE

During operation

Hot
Do not touch the blower outlet! The
blower outlet becomes hot during
operation!
AGA 45 / 75