3.4- Safety prescriptions
1. The supply voltage should correspond to that given on the description label (230 V ~ 50Hz).
Do not use any other type of power supply.
2. The pump should be supplied by a circuit containing a residual current device (circuit breaker, RCD) with
a sensitivity not exceeding 30 mA.
Consult with a qualified electrician.
3. The supply cable should be checked periodically and before each use to see if there are any signs of
ageing or damage.
If the pump is not in good condition, do not use it. Have it repaired by an authorized centre.
4. If an extension is used, ensure that it is officially approved. Keep it well away from sharp edges, heat
sources and combustibles.
5. The plug-in connector for the extension should be of the 2 pole + earth type of 10-16A/250V, in
accordance with EEC standards. The cable should not be lighter than H05 RN-F or H07 RN-F according to
model, with a wire section equal to or greater (refer to specs table).
6. When disconnecting the power cable from the socket, always grip the plug itself and not the cable.
7. If the pump is used for emptying a pond, it should not be used when there are people in the pond.
Similarly, to avoid accidents during pump operation: persons washing, swimming or in the water and
animals bathing or drinking around the operating area is strictly forbidden.
8. Do not transport, carry or hang the pump by its cable, use the carrying handle (if fitted).
IV. GETTING STARTED
Before any intervention on product, ensure that product is disconnected from its power source.
4.1- Unpacking
- Remove product from its packaging.
- Check that product and accessories are not damage
4.2- Important recommendations
Before connecting to the power source, you must observe the following:
- The device must be placed on a horizontal, leveled surface that is sufficiently capable of supporting the
total weight of the device when filled with water.
- Make sure that the power supply corresponds with the connection specifications of the device (see rating
label).
WARNING!
- The warranty does not cover accidents due to improper installation. This pump must be installed in
accordance with local standards and by a qualified person (we recommend you to contact an electrician).
- The fixed pipeline that will connect the pump must include a separation device having contacts with the
opening distance of at least 3 mm in all poles.
- It is recommended that the device be connected with a residual current of not more than 30 mA by means of a
residual-current-operated protective device
- The total head must not exceed the value stated on the Specifications Table.
- The cable must be at least cable [see specs table].
- To prevent vibrations, the device should be placed on an elastic support (e. g. a rubber mat).
- The installation site must be well ventilated and protected from the effects of weather.
- When being used near garden ponds and swimming pools, the device must be set up so as to guard against
overflowing and protected against falling in.
- Additional legal requirements must be observed.