Installation
Ceiling dimension and hanging bolt location
Installation of Unit
Install the unit above the ceiling correctly.
CASE 1
POSITION OF SUSPENSION BOLT
• Apply a joint-canvas between the unit and duct to absorb
unnecessary vibration.
• Apply a filter Accessory at air return hole.
Dimension
A
B
C
Capacity(Btu/h)
7/9/12/15k BTU/h 850 900 383 575
18/24k BTU/h 1130 1180 383 575
CASE 2
• Install the unit leaning to a drainage hole side as a figure
for easy water drainage.
POSITION OF CONSOLE BOLT
• A place where the unit will be leveled and that can support
the weight of the unit.
• A place where the unit can withstand its vibration.
• A place where service can be easily performed.
8
8
Indoor Unit
Indoor Unit
(Unit:mm)
D
E
F
G
H
I
93
190
21
795 163 820
93
190
21 1065 163 1100
J
Drainage hole
B
A
J
H
Drain Pump use
M10 Nut
X 4
(Local
M10 SP. washer
X 4
supply)
M10 washer
X 4
M10 washer
X 4
(Local
M10 SP. washer
X 4
supply)
M10 Nut
X 4