ESABMig C420sw/C420s
1
Mains supply switch
2
Switch, coarse control
3
Switch, precise control
4
Indicating lamp, power supply ON
5
Orange indicating lamp, overheating and
loss of coolant*
6
EURO – connector (for welding gun)
7
Connection for cooling water to the welding
gun (Blue – with ELP** switch)
8
Connection for cooling water from the weld-
ing gun (Red)
9
Connection for return cable (–), high induc-
tance
10
Connection for return cable (–), medium in-
ductance
11
Connection for return cable (–), low induc-
tance
12
Knob for wire speed setting / correction
* Indicating loss of coolant, only when water flow guard is used, see point 6.2.4
** ELP = ESAB Logic Pump, see point 6.2.3.
C420e
13
Knob for spot welding – ON/OFF and time
setting
14
Digital display for welding parameters
15
Switch for display selection – Volt. or Amp
16
Switch for display selection – m/min or mm
17
Lamp indicating status of synergy control
18
Lamps indicating recommended (–) current
output – max/med/min inductance
19
Switch for "Synergy"– ON/OFF and ma-
terial/gas selection
20
Knob for selection of the wire diameter
21
Knob for burn–back time setting
22
Mode selector 2–stroke /
23
Water flow guard (option,see page 238)