Process Connections
• Standard configuration
• High temperature option
• Cable configuration
Process seal (sensor to stainless steel body)
standard
optional (very high chemical resistance:
Process Conditions
• dielectric constant (εr)
3
• temperature
:
- standard configuration
- high temperature option
• pressure (vessel):
- standard configuration –1 to 35 bar g/–14.6 to 508 psi g/–100 to 3500 kPa g (nominal)
- high temp. option

Installation

Notes:
• Installation shall only be performed by qualified personnel and in accordance with local
governing regulations.
• This product is susceptible to electrostatic shock. Follow proper grounding procedures.
• The housing may only be opened for maintenance, local operation, or electrical
installation.
• Before installing the instrument, verify that the environment complies with any restrictions
specified on the device nameplate.
Mounting Location
Notes:
• Keep the sensor at least 50 mm (2") away from any nozzle or tank wall.
• If multiple units are used, allow at least 100 mm (4") between them, to prevent interference
(mount diagonally if space is restricted).
• Do:
provide a sun shield to protect the transmitter from direct heat radiation.
• Do not:
exceed the permissible ambient temperature limits (see page 5 for the analog
model, and page 10 for the digital model).
• Do not:
mount Pointek CLS 300 in locations subject to strong vibrations (if it can be
avoided).
1.
316L (1.4404) stainless steel.
2.
Standard and cable configuration only.
3.
At process connection.
7ML19985QF81
Pointek CLS 300 (analog/digital) – QUICK START MANUAL
1
¾
", 1", or 1 ½" BSPT or NPT; 1
¾
", 1", or 1 ½" BSPT or NPT; 1
1 ½" BSPT or NPT; 1
FKM/FPM (Fluoroelastomer) O-ring
FFKM/FFPM (Perfluoroelastomer) O-ring
1.5 minimum
–40 to 200
–40 to 400
–1 to 35 bar g/–14.6 to 508 psi g/–100 to 3500 kPa g (nominal)
¼
" NPT only
¼
" NPT only
¼
" NPT only
2
o
o
C (–40 to 342
F)
o
o
C (–40 to 752
F)
Page EN-3