Herunterladen Inhalt Inhalt Diese Seite drucken

Vacuum Cleaner Disposal; Wiring Diagrams - Nilfisk-ALTO ATTIX 170 Betriebsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 53

Vacuum cleaner disposal

Figure 20
Dispose of the vacuum cleaner in compliance with the laws
in force.
- Proper
disposal
(electric
(applicable in the European Union and in countries
providing a separate collection system)
The symbol shown in the figure is present on the product or in
its documentation and it indicates that the product cannot be
disposed of together with other domestic waste at the end of
its life cycle.
To prevent damages to the environment or the health caused
by improper waste disposal, please separate this product from
other waste and recycle it responsibly in order to support the
sustainable reuse of material resources.
Domestic users should contact the retailer or the local office
providing information on separate collection and recycling of
this product.
Companies should contact the supplier and check the purchase
contract terms and conditions.
This product can not be disposed of together with other
commercial waste.

Wiring diagrams

Class L (preset for cartridge filter and automatic
cleaning)
Figure 21
1
Power supply
2
Phase sequence relay
3
Vacuum cleaner
Figure 22
1
Transformer
2
Voltage signalling (white indicator)
Figure 23
1
Stop button
2
Start button
3
Vacuum cleaner contactor
4
Wrong phase sequence indicator (yellow indicator)
5
Vacuum cleaner switch-off delay timer
6
Mouth connection
Figure 24
1
Fuse box
2
Cartridge kit
3
Mouth connector
11/2008
and
electronic
waste)
13
Figure 25
Item
Description
H1
White lamp
H3
Yellow lamp
Contactor
KM1
kW4 24VAC 1NO
PA
Red button
PM
Green button
Q1
Circuit breaker 9-12,5 A
SF1
Phase sequence relay
TR1
Transformer 20 VA 400/24 V
KT1
24 VAC Timer
K1
24 VAC Relay
K2
24 VAC Relay
KC1
4P + T Connector
Class M and H (preset for cartridge filter and
automatic cleaning)
Figure 21
1
Power supply
2
Phase sequence relay
3
Vacuum cleaner
Figure 22
1
Transformer
2
Voltage signalling (white indicator)
Figure 26
1
Stop button
2
Start button
3
Vacuum cleaner contactor
4
Wrong phase sequence indicator (yellow indicator)
5
Vacuum cleaner switch-off delay timer
6
Mouth connection
7
Air speed sensor
8
Horn
Figure 27
1
Fuse box
2
Cartridge kit
3
Mouth connector
4
Speed sensor
5
Horn
Figure 28
Item
Description
H1
White lamp
H3
Yellow lamp
Contactor
KM1
kW4 24VAC 1NO
PA
Red button
PM
Green button
Q1
Circuit breaker 9-12,5 A
SF1
Phase sequence relay
TR1
Transformer 20 VA 400/24 V
KT1
24 VAC Timer
K1
24 VAC Relay
K2
24 VAC Relay
KC1
4P + T Connector
ATTIX 170 / ATTIX 170 E
Q.ty
1
1
1
1
1
1
1
1
1
1
1
1
Q.ty
1
1
1
1
1
1
1
1
1
1
1
1
C328
I
GB
F
D
E

Werbung

Inhaltsverzeichnis

Fehlerbehebung

loading