ATTIX 170 / ATTIX 170 E

Safety devices

1
Fan unit
2
Limiting valve
Do not tamper any setting.

Controls, indicators and connections

1
Container release lever
2
Castor lever
3
Manual filter shaker lever
4
Vacuum gauge
5
Main switch (ON "I", OFF "0")
6
"Clogged filter" indicator light (blue) (optional)
7
Reverse phase indicator light (yellow)
8
Stop-button (red)
9
Start-button (green)
10
Indicator light (electric panel voltage)
11
Electric filter shaker control button (yellow)
12
Connecting connector to mouth micro-switch
13
Horn for speeds below 20 m/s (M and H versions)

Inspection prior to starting

1
Inlet
2
Ø 70/50 Adaptor
3
Sleeve
4
Adaptor for Type 22 vacuum cleaners
5
Sleeve for Type 22 vacuum cleaners
I
Prior to starting, check that:
The filters are installed
All latches are tightly locked
GB
The vacuum hose and tools have been correctly fitted
into the inlet (1)
F
The bag or safety container is installed, if applicable
for Type 22 vacuum cleaners, check that the adaptor (4)
and the sleeve (5) of the suction hose are as shown.
D
E
Do not use the vacuum cleaner if the filter is faulty.
C328
Figure 5
WARNING!
Figure 6
Figure 7
WARNING!

Starting up

WARNING!
Lock the castor brakes (1) before starting the vacuum
cleaner.
To wire up the mouth start/stop remote switch (if equipped),
remove the connector (6) on the panel and use the connector
(7) supplied with the vacuum cleaner.
Starting/stopping the vacuum cleaner
Turn the main switch (2) to "I" position.
Press the button (3) to start the vacuum cleaner.
Activate the mouths (if equipped).
Press the button (5) to stop the vacuum cleaner.
Turn the main switch (2) to "0" position to turn the
vacuum cleaner off.
Checking the rotation direction of the vacuum unit motor
A check is automatically performed by the vacuum
cleaner and, if a faulty electrical connection is found, the
vacuum cleaner does not start and the yellow lamp (4)
turns on.
In these cases, unplug the vacuum cleaner and contact
qualified personnel in order to perform the correct phase
connection.
8
Figure 8