Commissioning
2
NOTE
The mounting instructions can be found in the operating instructions.
A Reference edge for the measurement
B Optical axis
C M12 device plug
D Receiver
E Transmitter
F Display/display element
G Yellow indicator diode – switching output state
H Green indicator diode – operating state
J Control buttons
NOTE
Degree of protection IP 67 is only achieved with correctly screwed-on connector!
3
NOTE
Information on the electrical connection, operation and commissioning can be
found in the operating instructions.
4
Analog output characteristic output curve (ODS9L....8/LA...-M12 only)
A Undefined range
B Linearity undefined
C Measurement range
D Object present
E No object detected (characteristic curve behavior adjustable via IO-Link)
F Measurement distance
NOTE
Starting at approx. 1500mm or 3000mm, "No Signal" is displayed and a value of
0V or 0mA is output at the analog output.