Contents
General info............................................................................
Dimensions and clearances...............................................
Installation .............................................................................
Operating limits ....................................................................
Refrigerant connections ....................................................
Electrical connections .........................................................
System configuration ..........................................................
System test .............................................................................
Pump down ............................................................................
Unit protection devices ......................................................
Maintenance ..........................................................................
Troubleshooting ...................................................................

General info

Before reading this manual please read carefully the safety
instruction booklet included in the outdoor instruction
package.
Use this unit only for factory approved applications:
for indoor unit codes and matching please refer to
the matching info sheet included in the outdoor unit
instructions package.
The unit code is stated on the outdoor nameplate data.
Models
38AW050H7
38AW065H7
38AW090H7 /
38AW115H7
38AW120H9 /
38AW150H9

Dimensions and Clearances

To dimensions see fig. 1
38AW050H7
38AW065H7
38AW090H7 /
38AW115H7
38AW120H9 /
38AW150H9
Outdoor unit - Air to water split
Page
A
B
C
mm
900
690
320
mm
900
820
320
mm
900 1360 320
mm
900 1360 320

INSTALLATION PROCESS

5
5
6/7
7
8
9/10
10
10
10
11
11
11
HYDRONIC CONNECTIONS
Mimimum installation clearances in mm are shown in fig.2
(single installation) and fig. 3 (serial installation)
Note:
49
The height of the obstacle at both front and rear side
51
should be lower than the height of the outdoor unit.
88
100
UNITS INSTALLATION
REFRIGRANT PIPES
DRAIN PIPE
UNITS WIRING
CONTROL WIRING
POWER WIRING
SYSTEM TEST
TROUBLESHOOTING
(Fig. 1 - 3)