Motor burnt out
6.4- Storage
- Clean the pump.
- Pump must be stored in a dry, ventilated location. Always lock up product and keep out of reach of
children.
6.5- Disposal
- Do not dispose the product with household garbage. Do not throw into the environment.
- Dispose of the product in a collection centre for waste of electrical and electronic equipment, or a waste
drop-off centre; or seek advice from your local municipality.
- Disposal of the product, accessories and packaging should be carried out according to local regulations
governing environment protection.
3. Stator winding burnt
1- Run too long with phase lost
2. Winding turn-to-turn short circuit
or short circuit between phases due
to mechanical seal leakage
3. Impeller clogged
4. Pump started to frequently
5. Pump overloaded
2. Remove foreign matter
3. Seek assistance from authorised service
centre
Seek assistance from vendor or authorised
service centre