Herunterladen Inhalt Inhalt Diese Seite drucken

sylvac ISP091201D Bedienungsanleitung Seite 18

Vorschau ausblenden Andere Handbücher für ISP091201D:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 41
12. Switching off
E
The dial gauge goes automatically into stand-by if not used for 20 minutes, unless Auto OFF mode has been turned off
(see Chap. 4, advanced functions)
Stand-by mode can be forced by a prolonged press (> 2 sec) on
In stand-by mode, the value of the origin is retained by the sensor (SIS mode), and the instrument automatically restarts
with any movement of the measurement probe, RS command, Bluetooth
The instrument can be switched off completely for a long period of non-use, but this will necessitate a zero reset on restart
(the origin will be lost) :
- Prolonged press (>4 sec) on
13. Re-initialising the instrument
The initial instrument settings can be restored at any time by a prolonged press (>4 sec) simultaneously on
until the message rESEt is displayed.
Nevertheless the instrument retains its configuration settings (units and resolution).
123.456
:
SET
request or press of a button.
®
SET
123.456
:
SET
mm
>4s
18
SET
mm
>2s
OFF
MODE
and
SET

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis