6
Installation
6.1
General
6.2
Preparation
Fig.116
Installation
6.3
Hydraulic connections
7659610 - v02 - 08032017
Note
Pursuant to Article L. 113-3 of the French Consumer Code, this
equipment must be installed by a certified operator whenever a re
frigerant connection is necessary (the case with split systems,
even when fitted with a quick coupling device).
6.2.1
Installation of the thermodynamic water heater
1. Separate the water heater from its pallet.
2. Level the water heater, fitting metal blocks under the water heater
feet if necessary.
Caution
Do not place the blocks on the external sides of the water heater.
Note
To allow condensates to drain easily from the appliance, install it
on a horizontal floor.
If this is not possible, the drain opening must be located at the
lowest point.
The angle of incline must not exceed 2°.
Caution
Before making the hydraulic connections, it is essential to flush
the domestic hot water circuits.
If flushing has to be done using an aggressive product, neutralise
the rinsing water before disposing of it in the waste water network.
Note
Using hoses which are too short or too rigid encourages the trans
mission of vibrations and the production of noises.
en
6 Installation
205